CellComSL
Series Communicator Install/Programming Guide
Digital Monitoring Products
15
COMMUNICATION
Communication
8.1
Communication
The Communication section allows you to configure the communication settings for the
CellComSL
Series Cellular Alarm Communicator. After choosing the Communication Type,
continue through the list of options.
8.2
Account Number
Enter the account num ber sent to the receiver.
CELL - The range of account numbers is 1 to 65535. For account numbers of four digits
or less, you do not have to enter leading zeros. The communicator automatically right
justifies the account number.
8.3
Transmission Delay
Enter the number of seconds (15 to 45 seconds) the
communicator waits before sending
burglary alarm reports to the receiver. Enter 0 (zero) to disable this function. The
default is 30.
If the area where the alarm occurred is disarmed during the Transmit Delay time, only
an Abort Report (S45) message is sent to the receiver. If the area where the alarm
occurred is disarmed after the alarm message is sent to the receiver but before the Bell
Cutoff time expires, even if the alarm was silenced, an Alarm Cancelled (S49) message is
sent. The Alarm Cancelled report cannot be disabled.
8.4
Communication Type
The c
ommunicator uses CELL communication to DMP Model SCS-1R or SCS-VR Receivers.
8.5
Test Time
Press COMMAND to enter the Test Time. Enter the time of day the
communicator sends
the test report to the SCS-1R or SCS-VR Receivers. Use entries between 12:00 to 11:59
and then choose AM or PM.
8.6
Cell Check In
Check-in reports are a method of supervising the panel for communication with the
receiver.
Enter the number of minutes between check-in reports. Select from 0 or 3-240 minutes.
Enter 0 (zero) to disable the check-in option. Default is 0.
Note:
If Cell Check-in option is used, additional cell charges may apply.
8.7
Fail Time
Fail Time allows the SCS-1R or SCS-VR receiver to miss a defined number of check-ins
before logging that the panel is missing. For example, if
CELL
CHECKIN
is 20 and
FAIL
TIME
is 30, the SCS-1R receiver only indicates a Panel Not Responding after 30 minutes.
The
FAIL TIME
must be equal to or greater than the
CELL CHECKIN
minutes: If the
CHECKIN is 20 minutes, the
FAIL TIME
must be 20 or more. The maximum
FAIL TIME
is
240 minutes. Select from 0 or 3-240 minutes. The default
FAIL TIME
is 240 minutes.
8.8
Receiver 1 Programming
Allows you to set the options for the first receiver the
communicator attempts to
contact when sending reports. The communicator supports communication to two
receivers.
8.9
Alarm Reports
YES enables Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit Error, and
System Recently Armed reports to be sent to this receiver. Default is YES
8.10
Supervisory/Trouble Reports
YES enables Supervisory, Trouble, Trouble Restoral, Force Armed, Late to Close, and
Fault reports to be sent to this receiver. Default is YES.
8.11
Opening/Closing and User Reports
YES enables Opening/Closing, Door Access, Schedule and Code Changes, and Bypass
reports by user to be sent to this receiver. Default is YES.
8.12
Test Report
Enter YES to enable the Recall Test report to be sent to this receiver.
8.13
First IP Address
Enter the first (primary) IP address where the
communicator sends cell messages. The IP
address must be unique and cannot be duplicated on the network. Enter all 12 digits and
leave out the periods. For example, enter IP address 192.168.0.250 as 192168000250.
The periods display automatically.
COMMUNICATION
ACCOUNT NO:
XMIT DELAY:
0
COMM TYPE:
CELL
TEST TIME
00:00
AM PM
CELL CHECKIN: 0
FAIL TIME: 240
RECEIVER 1 PROG
ALARM
NO
YES
SPV/TRBL NO
YES
O/C USER
NO
YES
TEST RPT
NO
YES
FIRST IP ADDR
000.000.000.000