Digital Monitoring Products, Inc. | 734N Installation and Programming Guide
9
734N
Interface
Module
Model 333
Supressor
Use the included 333 suppressor with the 734N to suppress any surges caused by energizing a
magnetic lock or door strike.
Install the 333 across the 734N
C
(common) and
NO
(normally open) or
NC
(normally closed)
terminals.
If the device being controlled by the relay is connected to the
NO
and
C
terminals, install the
suppressor on the
NO
and
C
terminals.
Conversely, if the device is connected to the
NC
and
C
terminals, install the 333 Suppressor on
NC
and
C
terminals.
The suppressor wire is non-polarized. Install the suppressor as shown in Figure 8.
4
INSTALL THE 333 SUPPRESSOR
Figure 8: 333 Suppressor Installation