Digital Monitoring Products, Inc. | 734INT Installation and Programming Guide
1
Annunciators
An onboard programmable piezo provides
local annunciation at the 734INT. You can
also connect a variety of switched ground
annunciators to the 734INT for remote
annunciation.
Indicator LEDs
The 734INT provides three indicator LEDs:
• RELAY (red) turns on for the same
duration as the door strike relay.
• WIEGAND (yellow) turns on for one
second to indicate receipt of valid input.
• DATA (green) indicates that the module
is communicating with the panel.
The 734INT Access Control Module allows you to use the powerful, built in access control
capability of DMP Panels using smartcard, proximity, mag stripe, or biometric readers, or
other compatible authentication devices. The 734INT includes the following features:
Power Supply
The 734INT operates at 12/24 VDC from
the power supply supporting a door’s
magnetic lock or door‑strike.
Warning:
To avoid the risk of
equipment damage, do not exceed
750 mA total output current for
zones connected to the module.
Zone Terminals
Zones 1 ‑ 4 on the 734INT can be
programmed for a variety of burglary or
access control applications.