Wiring Specifications

When planning an LX-Bus™ and keypad bus installation, keep in mind the following specifications:

1. DMP recommends using 18 or 22-gauge 

unshielded 

wire for all keypad and LX-Bus circuits. 

Do Not

 use 

twisted pair or shielded wire for LX-Bus and keypad bus data circuits. To maintain auxiliary power integrity 

when using 22-gauge wire do not exceed 500 feet. When using 18-gauge wire do not exceed 1,000 feet. 

Install an additional power supply to increase the wire length or add devices.

2. Maximum distance for any one circuit (length of wire) is 2,500 feet regardless of the wire gauge. This 

distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 

2,500 feet. As wire distance from the panel increases, DC voltage on the wire decreases.

3. Maximum number of devices per 2,500 feet circuit is 40.

 

Note:

 Each panel allows a specific number of supervised keypads. Add additional keypads in the unsupervised 

mode. Refer to the panel installation guide for the specific number of supervised keypads allowed.

4. Maximum voltage drop between the panel (or auxiliary power supply) and any device is 2.0 VDC. If the 

voltage at any device is less than the required level, add an auxiliary power supply at the end of the circuit. 

When voltage is too low, the devices cannot operate properly.

For additional information refer to the 710 Installation Sheet (LT-0310) and or the LX-Bus/Keypad Bus Wiring 

Application Note (LT-2031).

Certifications

California State Fire Marshal (CSFM)
FDNY COA #6167
UL 268 Smoke-Automatic Fire Detectors

Accessories

521LXTPCB Replacement Smoke Detector 

Board

525 Replacement Optical Chamber
526 Smoke! in a Can™

Trademark

CleanMe™ is a trademark of Sentrol, Inc.

Specifications

Operating Range 

8.8 to 15.0 VDC

Standby Current 

8.8mA

Alarm Current 

28mA

Maximum Ripple 

10% (V

p-p

) peak to peak

Sensitivity Photoelectric 

3.1% + 0.50 to 1.00%

Operating Temperature 

32°F to 100°F

Operating Humidity Range  0 to 95% non-condensing
RFI Immunity 

20V/m minimum; 0 to 1000MHz

Heat Sensor (LXT Only) 

135°F

Rate of Rise 

15°F/min and > 105°F

Power Up Time  

15 seconds

Drift Compensation  

1.0%/ft. max.

Detector Head Dimensions  5” Diameter, 2” Height
Mounting Dimensions 

4.75” Diameter, .3” Height

Color  

White Head and Base