ON
OFF
Opens
Clockwise
Opens
Counter-Clockwise
3.2 DIP-Switch Settings for 4100 Circuit Board
Switch
Function
Setting
Description
SW 1 (Top 8 Switches)
Operator
Opening
Direction
OFF
ON
OFF
ON
OFF
OFF
ON
6-
OFF
6-OFF
6-ON
6-ON
7-
OFF
7-ON
7-OFF
7-ON
Auto-Close
Timer
Accessory Power
Relay:
Main Terminals
Terminal 13-14
1
2
3
4
5
8
6 and 7
Switch
MUST
be turned
OFF
for Solar.
Auto-close timer is OFF. Manual input required to close gate.
Normal Setting.
Auto-close timer is ON. Adjustable from 1-23 seconds.
24 VDC 500 mA
accessory power
for accessories connected to main terminal 12.
DO NOT USE
for Solar.
OFF
ON
Quick-close feature is OFF.
Quick-close feature is ON. Opening gate will stop and begin to close as soon as
all reversing inputs (Reverse loops, photo sensors) are cleared regardless of the
distance the gate has opened. Used for slide gates only.
Normal Setting.
Relay activates when gate is at open limit.
Relay activates when gate is not closed.
Relay activates when gate is opening and open.
Relay activates during opening and closing cycle.
Changes direction
operator will cycle open
upon initial power up
and open command.
Reverses Gate
Not Used
Quick-Close
Timer Override
(Slide Gates
ONLY)
Not Used
Input to main terminal 10 and/or reverse loops will
reverse
gate during
close
cycle.
Do Not
use this setting for the 6524.
The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on
or off various operating features. Whenever a switch setting is changed, reset button must be pressed, located on circuit board
for the new setting to take affect.
OFF
ON
Main terminal 10 is a REVERSE input.
DO NOT USE
for solar power.
1-OFF
1-OFF
1-ON
1-ON
2-OFF
2-ON
2-OFF
2-ON
Select
Operator
Type
1 and 2
DO NOT USE
for the 6524.
Slide Gate Operator
Swing Gate Operator
DO NOT USE
for the 6524.
Barrier Gate Operator
DO NOT USE
for the 6524.
Overhead Gate Operator
Switch
Function
Setting
Description
SW 2 (Bottom 8 Switches)
Switches 7 and 8
MUST
be turned
OFF
for Model 6524 operator.
OFF
Reverse/Shadow
Input
Overlapping
Bi-Parting Gates
3
4
7 and 8
6
OFF
ON
5
Switch 5
MUST
be turned
OFF
for the 6524.
DO NOT USE
for solar power.
Overlapping gates
ARE
used (Dual swing gates
ONLY). Secondary gate starts to open a few seconds before primary gate starts.
OFF
ON
Input Power
Failure Mode
DO NOT USE
for Solar.
Gate
operates normally
until batteries get low. Gate will
CLOSE and Shutdown
operator
in close position until battery power reaches an operable level again.
OFF
ON
Circuit Board
Power
Management
DO NOT USE
for Solar.
For
115/230 VAC
input power. Board has
Constant power
.
Used for
Solar
input power. Board
Minimizes power
when not in use. All terminals
shut down power except
main terminals 1, 2
and
3
.
Not Used
Setting
MUST
be used
6524-066-G-7-16
1
8