![DKS 6524-081 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/dks/6524-081/6524-081_installation-and-owners-manual_2512747026.webp)
12345678
ON
12345678
ON
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
EXIT
LOOP
REVERSE
LOOP
AC POWER/SOLAR
POWER SEL
REV SENSE
JUMPER ON
SOLAR MODE
P3
SELF TEST
RESET
RED=CHARGING
GREEN=CHARGED
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF
ON
POWER
P4
P2
1
6
TIME DELAY
1 2 3 4 5 6 7 8 9 10
SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION
Com
to UL 325
Terminal
to UL 325
Terminal
24VDC 500 mA
MAX
ON
1
2
34567
8
SW 1
Photo Sensors POWER:
Terminal 12 supplies 24 VDC, 500 mA
of power for desired
accessories
.
SW1,
switch 8
MUST be OFF
4.1 UL 325 Terminal Description
Close Beam
Reversing Edge
Open Beam
Reversing Edge
Potential
Entrapment
Area
Potential
Hazard Area
Opening Gate
Closing Gate
Wall
Wall
UL 325 Terminal
External Entrapment Protection
Device Connection
Low V
oltage Common
Low V
oltage Common
CLOSE Edge
OPEN Edge
CLOSE Beam
OPEN Beam
1 2 3 4 5 6
7 8 9 10
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
External Entrapment Protection Devices:
In addition to the inherent reversing sensor system, this operator has a 6-pin UL 325 terminal for the connection of
photo sensors
-Type B1
and/or
reversing edges
-Type B2 entrapment protection required by UL 325 standards.
An external entrapment protection device MUST be
installed or the operator will NOT function.
Install these devices where the risk of entrapment or a safety hazard exists while the gate is
moving. Specific installations will vary.
DIP-switches
MUST
be turned
ON
for each device
wired to terminal.
ONLY connect monitored devices.
Potential
Entrapment
Area
Beam and Edge Inputs Note:
Open
and
Close
inputs will
activate in
EITHER
direction
of gate travel.
Low Voltage Common:
Common terminals for all the external
entrapment protection device inputs.
5
&
6
1
&
2
3
&
4
OPEN Beam & CLOSE Beam (Photo Sensor):
Obstructed opening-direction photo beam will
STOP
the gate
during the
opening-direction only.
Gate will resume the open cycle when the obstructed
photo beam has been cleared.
Obstructed closing-direction photo beam will
STOP
the gate
during the
closing-direction only.
Gate will resume the close cycle when the obstructed
photo beam has been cleared.
Note: The closing-direction photo sensor typically should
REVERSE
the gate
when the photo beam gets obstructed. See the next page for “Reverse”
closing-direction option.
OPEN Edge & CLOSE Edge (Reversing Edge):
Obstructed open-direction reversing edge will
Reverse
the gate
2 inches
and
STOP.
Another input is needed to open the gate.
Obstructed close-direction reversing edge will
Reverse
the gate
back to the open
position.
Another input is needed to close the gate.
Potential Entrapment Area:
If the
OPENING
gate could cause an entrapment, then installation
of a
MONITORED
entrapment protection device is
REQUIRED
.
Potential Entrapment Area:
If the
CLOSING
gate could cause an entrapment, then installation
of a
MONITORED
entrapment protection device is
REQUIRED
.
6524-066-G-7-16
22