3.3 General Programming Using the System Keypad
Proceed with the programming steps on the following pages
ONLY IF
PC programming
WILL NOT
be
used. The system keypad may be used to program some features on the telephone entry system but can
be a little tedious to use. We strongly suggest that you become familiar with the programming steps in
each feature you want to use
BEFORE
actually programming the system.
These steps will program Relay 1 and Relay 2 strike times. Strike times can be programmed from 1/4 second up to 99 seconds
by entering the desired time in seconds as a two-digit number in step 3.
Factory setting for relay strike times are: Relay 1 = 01 (1 sec), Relay 2 = 01 (1 sec).
3.3.1 Relay Strike Time
This programming sequence sets the maximum time allowed for conversation when the entry system places a call to the
resident. The talk time can be set from 1 second up to 255 seconds (4 minutes, 15 seconds) and is entered as a three-digit
number in step 3. The talk time set here
DOES NOT
affect the telephone numbers that are programmed under directory codes 0,
00, 000, 0000 and 1, 01, 001, 0001. The talk time for these two directory code sets are
factory set to the maximum.
Phone
numbers programmed under these directory codes should be reserved for management or emergency phone numbers that
generally require longer conversations.
Factory setting for talk time = 060 (60 seconds).
3.3.2 Talk Time
1.
Press and enter your four-digit MASTER CODE (
beep
).
2.
Press (
beep
) to set
Relay 1
, OR (
beep
) to set
Relay 2
strike time.
3.
Enter the
two-digit strike time
in seconds (00-99), then press (
beep
).
(Example: 1/4 second - enter 00, 1 second - enter 01 etc.)
4.
Repeat steps 2 and 3 to set other relay strike time.
5.
Press together to end this programming sequence (
beeeeeep
).
??
??
??
??
33
DEF
DEF
00
OPER
OPER
11
SP
SP
22
ABC
ABC
00
OPER
OPER
1.
Press and enter your four-digit MASTER CODE (
beep
).
2.
Enter the
three-digit talk time
in seconds (001-255), then press (
beep
).
(Example: 1 second - enter 001, 20 seconds - enter 020 etc.)
3.
Press together to end this programming sequence (
beeeeeep
).
??
??
??
??
88
TUV
TUV
00
OPER
OPER
00
OPER
OPER
Important Note:
If you make a mistake while programming, press keys at the same time
to escape from programming no matter how much has been completed, then begin again at step 1.