1834-065-B-10-14
20
NC
NO
ON
CLK
SEN
SPK
VOL
FEED
BACK
RS 232
MIC
VOL
OFF
RING
3 2 1
3 2 1
3
2
1
MASTER
CODE
KEYPAD
16AC
16AC
BAT
1NO
1NC
1C
2RY
2C
A
Z
IMC
5VDC
IMD
SPKR
COM
MIC
PSW
CGND
PHONE
CONTRAST
RS-232
12
Power Input Aux Terminal
Powers RS-232.
Black (Neg)
Red (Pos)
16.5 VAC
16.5 VAC
20 VA
Power
Input
20 VA
Relay 2 Jumper
Auxiliary Terminal
Relays
activate a door lock
or a gate operator for their
programmed strike time at
a controlled access point.
Power wire
polarity does
not matter.
Wiring
MUST
be twisted and
completely isolated from ground.
See section 2.1.4.
Power Transformers:
Use
ONLY
16.5 VAC, 20 VA UL Listed
Transformer.
BOTH
transformers
MUST
be installed for the
system to operate.
Run 18 AWG wire up to 100 Ft. Run 16 AWG wire up to 200 Ft.
See section 2.1.1, 2.1.3 and 2.1.4 for further information.
Ferrite
Filter
2.3 Telephone Entry System Wiring
PC Connection
See section 2.4.2 for wiring RS-232.
Relay 1 Input
Main Terminal
“BAT” & “COM” - 12 VDC Back-Up Battery Input
Back-up battery power.
“PSW” & “COM”
Switch Input -
See section 1.6 for Postal lock
connection.
A switch closure across these
terminals activates
Relay 1
for its
programmed strike time.
See section 3.2.6 Switch Input
Feature.
“PHONE”
“PHONE”
“1NO” - Normally Open (NO)
“1NC” - Normally Closed (NC)
“1C” - Common (C)
“2RY” - Contact (NO or NC)
“2C” - Common (C)
Relay 2 Input
“2RY” Contact is set NO or NC with
Relay 2 Jumper
on board.
See section 4.7
Central Office
Phone Line Input
touch tone, loop start
“CGND” Ground
See section 2.1.3.
Door Control
Gate Control
Door Locks
Gate Operator
Power for electric strike or magnetic
lock is
NOT provided
by the system.
Use separate UL listed power supply.
Magnetic lock
is wired to
the Normally Closed (NC)
relay input.
Electric strike
is wired
to Normally Open (NO)
relay input.
Gate Operator
is wired to
Normally Open
(NO) relay
input.
Lock Power
UL listed
To a Relay Input
To a
Relay Input
Door
Lock
See
section
2.1.5