Rated 

Voltage

Rated 

Current Draw

Input 

Type

Head 

Height

Flow Rate 

at Zero Head

Temperature

Rating

Product Dimensions 

(LxWxH)

Product 

Weight

Inlet Height 

from Base

Included 

Accessories

Wiring Color

References

CP-16

120 Volts / 60 Hz

1.9 Amps

USA 3-prong plug

16 ft. maximum

1.2 GPM 

• Continuous duty 140F°

• Max inlet temperature 160F°

• Not suitable for contact with 

   steam or gasses that exceed 160F°

4.5” x 10.75“ x 6.5” 

3.8 lbs. 

 

3.5” 

• Instruction Sheet

• Hang Tabs

• Plug Protector

• 4’ Remote Shutoff Leads

• Inlet Cover

Black - Live/Hot

White - Neutral

Green - Ground

All installations must conform to 

NEC requirements

220 Volts / 60 Hz (208-230)

1.0 Amps

NEMA 6-15 plug

16 ft. maximum

1.2 GPM 

• Continuous duty 140F°

• Max inlet temperature 160F°

• Not suitable for contact with 

   steam or gasses that exceed 160F°

4.5” x 10.75“ x 6.5” 

3.8 lbs. 

 

3.5” 

• Instruction Sheet

• Hang Tabs

• Plug Protector

• 4’ Remote Shutoff Leads with 

   Insulated Terminals

• Inlet Covers (3)

Brown - Live/Hot

Blue - Neutral

Green/Yellow - Ground

All installations must conform to 

NEC requirements

CP-16-230

Содержание CP-16

Страница 1: ...Installation and Safety Instructions CP 16 CP 16 230 Condensate Pump ...

Страница 2: ... 8 lbs 3 5 Instruction Sheet Hang Tabs Plug Protector 4 Remote Shutoff Leads Inlet Cover Black Live Hot White Neutral Green Ground All installations must conform to NEC requirements 220 Volts 60 Hz 208 230 1 0 Amps NEMA 6 15 plug 16 ft maximum 1 2 GPM Continuous duty 140F Max inlet temperature 160F Not suitable for contact with steam or gasses that exceed 160F 4 5 x 10 75 x 6 5 3 8 lbs 3 5 Instruc...

Страница 3: ...t forth above The Company shall not be liable for any costs or damage incurred by its customers in the removal or replacement of defective products from units in which the products have been assembled In no event shall the company be liable for loss of profits indirect consequential or incidental damages SAFETY WARNING FOLLOW ALL SAFETY INFORMATION TO REDUCE POTENTIAL ELECTRICAL SHOCK DISCONNECT P...

Страница 4: ...y scratch the pump s cover After opening the carton look for damage If damage is found file a claim with the freight carrier Connect power cord to a supply voltage and frequency that matches what is shown on the pump nameplate Source voltages lower than the rated supply can reduce performance and cause the pump to overheat The pump must be level and should be placed on a solid surface or floor The...

Страница 5: ...r the barb fitting and secure with a screw type hose clamp Route the tubing up and away from the pump avoid compressing or kinking the tubing The tube route should be the shortest possible distance from the pump to the building exterior or other drain location For best results the distance that the water must go UP should be shorter than the distance that it goes DOWN With the longer DOWN tubing t...

Страница 6: ...rming maintenance Periodically inspect the Pump tank to assure it is free of accumulated dirt or sludge Do not use solvent cleaners Clean Tank with soap and warm water only The check valve may be removed for cleaning or replace ment by unscrewing with a 9 16 wrench illustration Clean inlet and outlet piping Tubing may be cleared of slime or debris instantly with a Wagner brand Gallo Gun tool and S...

Отзывы: