background image

Limited Warranty

All pumps manufactured by or for DiversiTech Corporation (the Compa-

ny) and sold by the Company under the DiversiTech brand are warrant-

ed to be free of defects in workmanship and materials for a period of 

24 months from date of sale from the distributor to the contractor.  The 

Company will credit, repair or replace, at its option, any Pump if 

deemed defective within this time period.  All products returned to the 

Company must include a return authorization issued by the Company.  

The returned product should be suitably packaged and shipped 

prepaid from the point of shipment to the point designated in the 

Company's return authorization. 

This warranty is a limited warranty and shall be in lieu of any other 

warranties, expressed or implied, including, but not limited to, any 

implied warranty of merchantability or fitness for a particular purpose. 

There are no other warranties that extend beyond the description of 

the face hereof.  The liability of the Company arising out of it's supply of 

said products, or their use shall not in any case exceed the cost of 

correcting defects in the products as set forth above.  The Company 

shall not be liable for any costs or damage incurred by its customers in 

the removal or replacement of defective products from units in which 

the products have been assembled.  In no event shall the company be 

liable for loss of profits, indirect, consequential, or incidental damages.

SAFETY WARNING

FOLLOW ALL SAFETY INFORMATION TO REDUCE POTENTIAL ELECTRICAL SHOCK. 

DISCONNECT POWER BEFORE SERVICING UNIT.  PUMP MUST BE PROPERLY GROUNDED.

NEVER USE THE PUMP TO MOVE FLAMMABLE LIQUIDS.

NEVER USE THE PUMP IN AN EXPLOSIVE GAS ENVIRONMENT, 

OR WHERE GAS FUMES OR VAPOR MAY BE PRESENT.

ALWAYS DISCONNECT THE POWER PRIOR TO MOVING, 

ADJUSTING OR SERVICING THE PUMP OR ATTACHED SYSTEMS. 

WARNING: RISK OF ELECTRIC SHOCK

THIS PUMP MUST BE PROPERLY CONNECTED TO POWER FOLLOWING THE NATIONAL 

ELECTRIC CODE (NEC). FAILURE TO FOLLOW THESE WARNINGS WILL VOID WARRANTY AN

 COULD RESULT IN AFATAL ELECTRIC SHOCK. A GREEN LED WILL INDICATE IF POWER IS 

AVAILABLE. THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND GROUND-

ING-TYPE ATTACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC SHOCK, BE CERTAIN THAT 

IT IS CONNECTED ONLY TO A PROPERLY GROUNDED, GROUNDING-TYPE RECEPTACLE. 

DiversiTech Corporation

6650 Sugarloaf Parkway

Suite 100

Duluth,GA 30097

800.995.2222

FAX 770.593.8600

©2019 DiversiTech Corporation

PRINTED IN VIETNAM

Содержание CP-16

Страница 1: ...Installation and Safety Instructions CP 16 CP 16 230 Condensate Pump ...

Страница 2: ... 8 lbs 3 5 Instruction Sheet Hang Tabs Plug Protector 4 Remote Shutoff Leads Inlet Cover Black Live Hot White Neutral Green Ground All installations must conform to NEC requirements 220 Volts 60 Hz 208 230 1 0 Amps NEMA 6 15 plug 16 ft maximum 1 2 GPM Continuous duty 140F Max inlet temperature 160F Not suitable for contact with steam or gasses that exceed 160F 4 5 x 10 75 x 6 5 3 8 lbs 3 5 Instruc...

Страница 3: ...t forth above The Company shall not be liable for any costs or damage incurred by its customers in the removal or replacement of defective products from units in which the products have been assembled In no event shall the company be liable for loss of profits indirect consequential or incidental damages SAFETY WARNING FOLLOW ALL SAFETY INFORMATION TO REDUCE POTENTIAL ELECTRICAL SHOCK DISCONNECT P...

Страница 4: ...y scratch the pump s cover After opening the carton look for damage If damage is found file a claim with the freight carrier Connect power cord to a supply voltage and frequency that matches what is shown on the pump nameplate Source voltages lower than the rated supply can reduce performance and cause the pump to overheat The pump must be level and should be placed on a solid surface or floor The...

Страница 5: ...r the barb fitting and secure with a screw type hose clamp Route the tubing up and away from the pump avoid compressing or kinking the tubing The tube route should be the shortest possible distance from the pump to the building exterior or other drain location For best results the distance that the water must go UP should be shorter than the distance that it goes DOWN With the longer DOWN tubing t...

Страница 6: ...rming maintenance Periodically inspect the Pump tank to assure it is free of accumulated dirt or sludge Do not use solvent cleaners Clean Tank with soap and warm water only The check valve may be removed for cleaning or replace ment by unscrewing with a 9 16 wrench illustration Clean inlet and outlet piping Tubing may be cleared of slime or debris instantly with a Wagner brand Gallo Gun tool and S...

Отзывы: