First Stage Torque Specifications
(2) For a successful rebuild, it is necessary to use proper torque on all connections that require it. The
following specifications should be used, listed in the order they occur in the assembly:
Nut (16) to Port Swivel (23) to End Cap (19)
70 in lbs/81 kgf cm/7.9 Nm
HP Seat Retainer (33) to Body (11)
130 in lbs/150 kgf cm/15 Nm
Filter Retainer (D10) to Body (11)
260 in lbs/300 kgf cm/30 Nm
Retainer Housing (D8) to Filter Retainer (D10)
86 in lbs/100 kgf cm/9.7 Nm
Shutter Valve (D2) to Retainer Housing (D8)
27 in lbs/31 kgf cm/3 Nm
Port Plugs (21, 24)
35 in lbs/40 kgf cm/4 Nm