2. Remove the Heat Sink Nut (05) - Fig. 6. Holding the Lever (18) down, slide/pull the Adjust Tube
assembly out of the Main Housing as one unit - Fig. 7. Inspect the Exhaust Valve (11*) by using a pick
or dowel and gently press all around the edge to check that it is pliable and not stuck or torn. – Fig. 8.
Fig. 6 Fig. 7 Fig. 8
3. Slide the Deflector Knob (16) off the assembly while holding down the Lever - Fig. 9. After sliding the
Deflector Knob off, carefully allow the Lever to come up slowly. Remove the O-ring (15*) from the
Deflector Knob and O-ring (04*) from the inlet side of the Main Housing - Fig. 10.
Fig. 9 Fig. 10