26
ENG
DEU
Commissioning
ENG
The pump control is activated or deactivated directly at the base station, or with an room control unit
Display.
6.4.1 Activation/deactivation of the pump control (base station)
1. Press the Select key (B) of the base station approximately for 4 seconds, until the LED of heating
zone 1 flashes in green:
Display
Meaning
0
0,1
0,2
0,3
0,4
HZ1
Duration in seconds
Pump inactive
(UnP1: P025, value 4)
0
0,5
1,0
1,5
2,0
HZ1
Duration in seconds
Pump active
(UnP1: P025, value 0)
2. Toggling the pump from active to inactive or vice versa: Press the Select key (B) for 4 seconds.
3. Leaving the menu without changes: Press the Select key shortly.
6.4.2 Activation/deactivation of the pump control (Room control unit Display)
With the DITECH Smart Home iL room control unit Display, different parameters can be assigned to
the pump control. For this, the parameter P025 in menu UnP1 (see „Configuration“ page 29) must
be changed according to the requirements.
For parametrisation, one room control unit must have been taught in to heating zone 1. This
device can be used for further heating zones.
7 Commissioning
For the commissioning of the DITECH Smart Home iL base station, at least one DITECH Smart Home
iL room control unit Display, Display S or Analog must be taught-in to the base station. As an alterna-
tive, the base station can be integrated to the DITECH Smart Home iL central unit via the app into the
DITECH Smart Home iL system. If used without central unit, the base station must be configured via
the DITECH Smart Home iL room control unit Display.
1. Establish the electrical supply of the DITECH Smart Home iL base station.
9
All heating zones of the base station are activated for 10 minutes in order to unlock the first-open
function of connected actuators.
9
A 2-point regulation is performed in the first 30 minutes after the initial voltage supply.
2. Proceed with section 7.1 or 7.2 depending on the system configuration.
7.1 Teach-in without DITECH Smart Home iL central unit (stand-alone operation)
Keep a minimum distance of 50 cm between the devices for teaching-in.