Commissioning
44
ENG
DEU
ENG
5.2.2 Installation with screws
1. Select a suitable installation position.
2. Ensure that no lines are laid at this position.
3. Remove the mounting plate from the device.
4. Position the mounting plate on the installation place. The arrow on the front
of the mounting plate must show upwards.
5. Align the mounting plate horizontally.
6. Mark two diagonally opposite bores using the mounting plate as a template
(see P in fig. 2).
7. For stone walls, drill the marked holes with a 5 mm masonry drill.
If wooden walls are present, the screws can be directly screwed into the
wood. Pre-drilling with a 1.5 mm wood drill facilitates the screw installation.
8. Insert the dowels into the bores.
9. Install the mounting plate with the supplied screws (see fig. 3 page 4).
10. Install the interchangeable frame onto the mounting plate.
11. Position the device onto the mounting plate and latch it into the clips.
5.2.3 Installation on flush-type box
The fixing holes in the mounting plate can be used for installation onto a flush-type box.
1. Remove the mounting plate from the room control unit Display.