max. 5 cm
2
+
-
*
*
***
**
**
IN
TE
R
FA
C
E
**
+
-
+
-
2.2 m
2.2 m
2.2 m
2.2 m
RADAR OPENING IMPULSE FIELD
ANGLE
WIDTH
4 m x 2 m (wide)
2 m x 2.5 m (narrow)
field size: 9
immunity: 2
field size: 9
immunity: 2
field size: 9
immunity: 2
field size: 9
immunity: 2
The size of the detection field varies according to the mounting height of the sensor.
In emergency exits the full door width must be covered.
from 15° to 45°, default 30 °
from -15° to 15°, default 0°
ENGLISH
MOUNTING
WIRING
WITH INTERFACE
WITHOUT INTERFACE
GREEN
BROWN
YELLOW
WHITE
PINK
GREY
RED
BLUE
YE/BK +
WH/BK -
GREEN
BROWN
GREY
YELLOW
WHITE
PINK
RED
BLUE
YE/BK +
WH/BK -
* Output status when sensor is operational
** For compliance with EN 16005 and DIN 18650, connection to door controller test output is required.
***Current source output for emergency exits
POWER SUPPLY
OPENING INPUT
SAFETY INPUT
TEST OUTPUT
OPENING INPUT
FOR EMERGENCY
EXITS
SE
NS
OR
IMPORTANT!
The radar output parameter has to be set to
« current output « (factory value).
Door control without test:
connect red and blue wires
to power supply
Monitored inner impulse
Inner impulse
Presence impulse
Presence impulse (0 V)
Monitoring presence impulse
(24V)
Monitoring presence impulse
(0 V)
Make sure the black cable
sleeves are placed on the side
of the controller!
POWER SUPPLY
Controller
Controller
PAS024AMR: INSTALLATION GUIDE