ASSA ABLOY Entrance Systems AB hereby declares that the PAS024AMR is in conformity with the European directives
2014/53/EU (RED), 2006/42/EC (Machinery) and 2011/65/EU (ROHS).
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 13089624
Landskrona, february 2021 Matteo Fino, authorized representative and responsible for technical documentation
This product should be disposed of separately from unsorted municipal waste
TECHNICAL SPECIFICATIONS
Supply voltage:
Power consumption:
Mounting height:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Presence
Typical response time: < 200 ms (max. 500 ms)
Active infrared with background analysis
Spot: 5 cm x 5 cm (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
Solid-state-relay
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
Holdtime: 0.3 to 1 s
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
Holdtime: 0.3 to 1 s
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms
The external monitoring is active by default
EN ISO 13849-1 PL «c» CAT. 2
(under the condition that the door control system monitors
the sensor at least once per door cycle)
EN 16005
(protective devices)
DIN 18650-1
(protective devices)
EN 12978
Motion
Min. detection speed: 5 cm/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm
2
Open-collector transistor
Max. sink current: 20 mA
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
- in switching mode: NO/NC
- in frequency mode: pulsed signal
(f= 100 Hz +/- 10%)
- in inverted frequency mode: pulsed signal
in detection (f = 2.5 Hz)
Galvanically isolated current source
No detection: current source ON
Open circuit voltage: 6.5 V
Output voltage available at 10 mA: 3 V min.
Typical load: up to 3 optocouplers in series
Detection: current source OFF
Open-circuit remained voltage: < 500 mV
Detection mode:
Technology:
Output PAS024AMR:
( interface)
Output PAS024AMT:
(sensor only)
Test input:
Safety Standards:
Specifications are subject to changes without prior notice.
All values measured in specific conditions.
12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10%
< 2.5 W
2 m to 3.5 m
-25°C to +55°C; 0-95% relative humidity, non condensing
IP54
< 70 dB
20 years
PL
EA
SE K
EE
P F
O
R F
U
R
TH
ER U
SE - D
ES
IG
N
ED F
O
R C
O
LO
U
R P
R
IN
TI
N
G
* The Equipment must be powered by a SELV limited
power source ensuring double insulation between pri-
mary voltages and the Equipment supply. The supply
current should be limited to max 3A.