Service - 160
RT45 Operator’s Manual
1000 Hour
1000 Hour
Change Differential Oil
Change differential oil every 1000 hours.
To change:
1.
Remove cover and drain oil.
2.
Replace cover.
3. Add MPL at fill plug until oil is visible at plug.
•
For model 44 differentials, capacity is 5 pt
(2.3 L) for front and 5.5 pt (2.6 L) for rear.
•
For model 60 differentials, capacity is 5.9
pt (2.8 L) for front and rear.
Change Ground Drive Gearbox Oil
Change ground drive gearbox oil every 1000
hours.
To change:
1.
Remove drain plug (3).
2.
Drain oil and replace plug.
3. Add MPL at fill (1) until oil comes out at check
plug (2). Capacity is 2 pt (0.96 L).
Location
Task
Notes
TRACTOR
Change differential oil
MPL
Change ground drive gearbox oil
MPL
Change hydraulic fluid and filter
THF
Содержание RT45
Страница 1: ...RT45 Operator s Manual 053 1982 Issue 4 0 ...
Страница 7: ...Overview 6 RT45 Operator s Manual ...
Страница 70: ...RT45 Operator s Manual Drive 69 Drive Chapter Contents Start Unit 70 Drive 72 Shut Down 72 ...
Страница 84: ...RT45 Operator s Manual Trench 83 Trench Chapter Contents Setup 84 Operation 85 ...
Страница 99: ...Saw 98 RT45 Operator s Manual Operation ...
Страница 100: ...RT45 Operator s Manual Backhoe 99 Backhoe Chapter Contents Setup 100 Operation 101 Dig 101 Move Unit 101 Stowing 102 ...
Страница 105: ...Backhoe 104 RT45 Operator s Manual ...
Страница 125: ...Microtrenching 124 RT45 Operator s Manual Operation ...
Страница 136: ...RT45 Operator s Manual Service 135 Lubrication Overview Lubrication Overview ...
Страница 175: ...Service 174 RT45 Operator s Manual As Needed ...
Страница 193: ...Specifications 192 RT45 Operator s Manual MT12 MicroTrencher ...
Страница 196: ......
Страница 197: ......
Страница 198: ...RT45 Operator s Manual Service Record 197 Service Record Service Performed Date Hours ...
Страница 199: ...Service Record 198 RT45 Operator s Manual Service Performed Date Hours ...