2002
Directed Electronics, Inc.
23
System Features Menus
Menu #1 - Basic Features
Items in bold text have been programmed to the default setting at the factory.
Menu #2 - Remote Start Features
Feature
Default LED ON Setting
LED OFF Setting
Number
(Press Channel 1)
(Press Channel 2)
2-1
Engine Checking ON
Engine Checking OFF
2-2
Tachometer checking type
Voltage checking type
2-3
12 minutes run time
24 minutes, 60 minutes run time
2-4
Flashing parking light output
Constant parking light output
2-5
Cranking time 0.6 sec. (1)*
Cranking time - 0.8 (2), 1.0 (3), 1.2 (4),
1.4 (5), 1.6 (6), 1.8 (7), 2.0 (8), 4.0 (9)*
2-6
High voltage check level
Low voltage check level
2-7
Auxiliary output - factory disarm
Auxilliary output - special accessory
2-8
Normal status output
Factory rearm output
2-9
Anti-grind ON
Anti-grind OFF
*
NOTE: The numbers in parentheses indicate the number of times the LED will flash.
Feature
Default LED ON Setting
LED OFF Setting
Number
(Press Channel 1)
(Press Channel 2)
1-1
Active arming
Passive arming
1-2
Chirps ON
Chirps OFF
1-3
Ignition controlled door locks ON
Ignition controlled door locks OFF
1-4
Active locking only
Passive locking
1-5
0.8 second door lock pulses
3.5 second door lock pulses
1-6
Double pulse unlock OFF
Double pulse unlock ON
1-7
Channel 2 output - delayed validity (1)*
Channel 2 output - Instant validity
(2)/latched (3)/latched reset with
ignition (4)/30-second timed (5)/
second unlock (6)*
1-8
Factory disarm with Channel 2 ON
Factory disarm with Channel 2 OFF
1-9
Code Hopping ON
Code Hopping OFF
*
NOTE: The numbers in parentheses indicate the number of times the LED will flash.