26
©
2002
Directed Electronics, Inc.
2-3 RUN TIME 12/24/60 MINUTES:
This feature controls how long the engine will run
before it “times out” and shuts down. Programmed to the default setting the engine will
run for 12 minutes. If the 24- or 60-minute run time is desired, press the unlock button of the
transmitter. The LED will blink two times for 24 minutes and three times for 60 minutes.
2-4 PARKING LIGHTS FLASHING/CONSTANT:
In the default setting, the unit will flash the
vehicle’s parking lights while remote started. The constant setting will turn the parking lights on
solidly for the entire run duration.
2-5 CRANK TIME 0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0:
If Feature 2-2 is programmed to the voltage
sense setting, the crank time must be set to the appropriate duration. The default setting is 0.6
second. If a different crank time is desired, select Feature 2-5 and (while pressing the
Valet®/Program switch) advance to the next time by pressing the unlock button. The unit will flash
the LED to indicate which time is selected. Continued pressing of the unlock button will cycle
through all LED off settings.
2-6 VOLTAGE CHECK LEVEL HIGH/LOW:
This feature only functions when Feature 2-2 is
programmed to voltage sense. Some vehicles have many accessories, which are turned on when
remote started. In these vehicles, the variation of voltage between the engine off and the vehicle
running is very slight and the remote start unit may “think” the vehicle has not started. This can
cause the remote start to shut down after the vehicle has been started. If this is the case, program
this feature to the LOW position.
2-7 AUXILIARY OUTPUT:
In the default setting the LT. GREEN/BLACK, H2/2, wire sends a
negative pulse that may be used to disarm the vehicle’s factory security system. If programmed for
an ignition three output, the wire can be used to energize a relay to power up extra ignition wires
in the vehicle.
2-8 BLUE WIRE STATUS OUTPUT/FACTORY RE-ARM OUTPUT:
The blue (H3/1) wire will
supply a (-)200mA output for the entire remote start run time. If programmed for factory re-arm
output, this wire will supply a momentary (-)200mA pulse whenever the remote start times out or
is shut down with the transmitter. This can be used to re-arm many factory security systems.
2-9 AUTOMATIC ANTI-GRIND ON/OFF:
With the anti-grind on (default) the ground-when-
armed output will be active during remote start operation. If accessories such as a voice module or
window module are added to the unit, it may be necessary to program this feature off.
Содержание PYTHON 480XP
Страница 35: ......
Страница 36: ...Wiring Quick Reference Guide...