Host x 1 

 

Sample cup / tray x 1 

 

Flat scraper x 1 

 

USB cable x 1 

 

Calibration plate x 1 

 

User manual x 1 

 

Carry bag x 1 

 

 

 

 

Please read this manual carefully before using the product. 

 

If  the  product  is  found  to  be  overheated,  producing  smoke  or  unpleasant 

smell,  unplug  the  power  cord  and  turn  off  the  power  switch  immediately. 

Continue use may cause fire or electric shock. 

 

If repair service is required, please contact the dealer from which the product 

is purchased. 

 

Do not operate the product when hands are wet and when connecting the 

charger to the equipment to avoid the risk of electric shock. 

 

This is not a waterproof and dust-proof product, operating in a temperature 

between 0~40°C, relative humidity within 80%. 

 

Do not use a charger exceeding 5 volts, otherwise it will cause damage. 

 

This product is a precision optical instrument. If the sensor or light source is 

contaminated, the accuracy of the measurement will be affected. Keep the use 

and storage place clean. 

 

When using the equipment, stay away from places where static electricity or 

magnetic  fields  might  occur,  so  as  not  to  affect  measurement  accuracy  or 

increase the risk of failure. 

 

Do not use on uneven or vibrated work surface, or the product may be fallen 

or shaken, resulting in injury, product failure or inoperability. 

 

The product has built-in lithium batteries and precision electronic circuitry.  If 

it encounters fall, heavy hit, collision or other external force injury causing the 

deformation of the product, stop using the product immediately and place in 

a safe place. 

 

Do not use damaged power cords, power plug, or loose connectors. This may 

result in a short circuit, fire or electric shock to the wires. 

Package contents

 

Precautions

 

Содержание KN-201

Страница 1: ...Coffee Roast Analyzer KN 201 User manual Made in Taiwan Version 1 1 6...

Страница 2: ...technology complies with the SCA Roast Color Classification System which enables a coffee roaster accurately measuring the coffee beans Agtron number and the roasting degree name This product uses th...

Страница 3: ...low degree However as the market evolved this type of measuring method is gradually replaced by other measuring equipment that turned to the primary use of assessing the degree of roasting Agtron Gour...

Страница 4: ...s otherwise it will cause damage This product is a precision optical instrument If the sensor or light source is contaminated the accuracy of the measurement will be affected Keep the use and storage...

Страница 5: ...und measurements Self adaptability design error automatic compensation Comply with standard SCA Agtron scales Gourmet and Commercial Display Roast degree name SCA and Common support 200 data logs of h...

Страница 6: ...e short press to start measurement for ground coffee Micro USB To connect the USB charger Charging indicator Orange light indicates charging is in progress and green light indicates charging is comple...

Страница 7: ...tes that charging is in progress When showing Full Charged means the battery is fully charged and the charging will automatically stop This product supports charging and operating the measurement work...

Страница 8: ...er or not it levels with the edge of the cup when filling and flattening the sample cup are the two most important points that will affect the measurement accuracy When placing coffee in the sample cu...

Страница 9: ...er and the corresponding two roasting degree names The name of the SCA definition shows above the Agtron number the common name shows under Over Range is shown when the measured value is outside the r...

Страница 10: ...side of the calibration plate on a flat surface then place the KN 201 on the calibration plate Make sure there is a solid fit all around Press and hold Ground Setting button for more than 3 seconds to...

Страница 11: ...se accuracy When carrying out calibration the ambient temperature should be kept in the range of 25 5 C Temperature outside of this range may affect the accuracy of the calibration After the calibrati...

Страница 12: ...g to select the item options The options are displayed in the table below Item Option Description 1 Auto Power Off 1 Always ON 2 5 mins 3 10 mins 4 30 mins 5 60 mins The default is 30 minutes When the...

Страница 13: ...e the charging cable before cleaning Exterior cleaning The body shell and sample cup plate can be wiped with a micro wet fine fiber cloth and then with a dry cloth to remove the surface moisture Pleas...

Страница 14: ...it use a small amount of soft dishwashing liquid and then rinse with water dry quickly with soft paper towels or cloth The process must be gentle to avoid surface scratches Do not clean light sources...

Страница 15: ...ED Sensor Multi point phototransistors Warm up time 30 seconds Measure range 0 150 Agtron Gourmet number Accuracy 99 Data records 200 records Battery High capacity rechargeable polymer lithium battery...

Отзывы: