background image

Dipl.-Ing. H. Horstmann GmbH 

Instructions for Use 

4  

SMART 

NAVIGATOR 

C

OMPLIANCE 

S

TATEMENTS

 

 

R

EGULATORY 

I

NFORMATION FOR THE 

U

NITED 

S

TATES OF 

A

MERICA

 

 
 

Warning 

Installation, connection and commissioning of the SMART NAVIGATOR  must be 
carried out exclusively by a skilled/qualified electrician observing the applicable 
safety rules and regulations. 

Attention 

This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions: (1) this device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that 
may cause undesired operation 

Warning 

Changes or modifications to the SMART NAVIGATOR not expressly approved by 
Dipl.-Ing. H. Horstmann GmbH could void the user's authority to operate the 
equipment.  

 
SMART NAVIGATOR FCC ID: 

YQVHHH001 

 
 

R

EGULATORY 

I

NFORMATION FOR 

C

ANADA

 

 
 

Warning 

Installation, connection and commissioning of the SMART NAVIGATOR must be 
carried out exclusively by a skilled/qualified electrician observing the applicable 
safety rules and regulations. 

Attention 

Operation is subject to the following two conditions: (1) this device may not cause 
harmful interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation 

Warning 

Changes or modifications to the SMART NAVIGATOR not expressly approved by 
Dipl.-Ing. H. Horstmann GmbH could void the user's authority to operate the 
equipment.  

 
SMART NAVIGATOR IC:

 9199A-HHH001

 

 

 
 

R

EGULATORY 

I

NFORMATION FOR 

E

UROPE

 

This instrument is in conformity with the requirements of the EC Electromagnetical Compatibility 
(EMC) Directive and the EC Low Voltage (LVD) Directive in the current state of issue. 

If required, the 

 -Declaration of Conformity may be obtained from the following address: 

 

   Dipl.-Ing. 

H. 

Horstmann 

GmbH 

Humboldtstraße 2 

42579 Heiligenhaus 

[email protected] 

Содержание SMART NAVIGATOR

Страница 1: ...Dipl Ing H Horstmann GmbH Humboldtstra e 2 42579 Heiligenhaus www horstmanngmbh com Instructions for Use SMART NAVIGATOR 14 September 2010...

Страница 2: ...ation and Reset 8 2 2 3 Fault Indication and Line Monitoring by Radio Signal 9 2 3 Wireless Communication 9 2 3 1 Priority Events communicate by exception 9 2 3 2 Reports communicate by routine interv...

Страница 3: ...ice here _______________________________ You will find all data on the name plate attached to the housing of the instrument The content of this operating manual reflects the current state of the art a...

Страница 4: ...INFORMATION FOR CANADA Warning Installation connection and commissioning of the SMART NAVIGATOR must be carried out exclusively by a skilled qualified electrician observing the applicable safety rule...

Страница 5: ...VIGATOR Part 4 Technical Data Contains the technical data of the Navigator SMART NAVIGATOR 1 2 ABBREVIATIONS Abbreviation Definition DA Distribution Automation FCI Faulted Circuit Indicator ISM Indust...

Страница 6: ...ine section This substantially speeds up the process of restoring the power supply to the utility customers In addition the SMART NAVIGATOR continuously monitors and transmits circuit status informati...

Страница 7: ...Instructions for Use Dipl Ing H Horstmann GmbH SMART NAVIGATOR 7 PART 2 FUNCTIONALITY 2 1 DEVICE DESCRIPTION Figure 2 1 NAVIGATOR 2D View Battery Compartments...

Страница 8: ...The SMART NAVIGATOR features one ultra bright RED LED that provides fault information LED Status Meaning Off Normal status of FCI 1 RED LED Flashing Fault Indication Fault detection is indicated by a...

Страница 9: ...EIVER via low power RF wireless technology using the world wide available 2 4GHz ISM Industrial Scientific Medical frequency band The range between the SMART RECEIVER and a SMART NAVIGATOR can extend...

Страница 10: ...TEST with a magnet for 0 2s does test the local indication and radio link It turns the FCI ON and activates a local fault indication LED flashing The unit will be flashing until reset by magnet elapse...

Страница 11: ...overhead line The field replaceable battery provides operational power Not only dependent on line current or voltage for its power the fault indicator is constantly armed ready to register switching i...

Страница 12: ...Installation should be carried out observing appropriate safety regulations and the use of proper protective equipment such as hot sticks Operators must maintain safe clearance from electrical power...

Страница 13: ...r momentary fault information 3 Low battery Whenever a SMART NAVIGATOR detects that its battery is approaching its end of life it sends the Low Battery information 4 Test FCI ON Activating the reed co...

Страница 14: ...or pairing with a SMART NAVIGATOR Step 3 Hold the magnet close to the RESET point of the SMART NAVIGATOR until a yellow LED in the SMART NAVIGATOR lights up twice If after a maximum of 10 seconds eith...

Страница 15: ...factor 4 times load current 200ms Level delay 60 sec Level memory 72 hours Function test reset by use of permanent magnet Automatic time reset 4 hours Current reset 3 A Power source 1 Lithium Battery...

Страница 16: ...Dipl Ing H Horstmann GmbH Instructions for Use 16 SMART NAVIGATOR 4 1 PRODUCT FOTO LABEL INFORMATION Label with FCC ID IC ID...