4 OF 5
IG050919-4.0
DMX ZONE CONTROLLER
INSTALLATION GUIDE
SYSTEM DIAGRAM
The following diagram is provided as an example system design. CAT5 (RJ45 connections) data cables are the most cost-effective solution for
transmitting DMX-512 signals. XLR-3 cables may also be installed but require an additional adapter for connecting to DMX decoders. Always review
each component installation guide for detailed and up-to-date wiring instructions. Install in accordance with NEC and local regulations.
AC Power
50/60Hz
L
N
Class 2 12-24VDC Driver**
Installed in Junction Box‡
G*
N
L
Input
Output
V+
V-
V+
V-
V+
CH1 - R
CH2 - G
CH3 - B
CH4 - W
0-5 0-9 0-9
Data IN
Data OUT
V+
V-
V+
CH1 - R
CH2 - G
CH3 - B
CH4 - W
0-5 0-9 0-9
Data IN
Data OUT
AC Power
50/60Hz
L
N
Class 2 12-24VDC Driver**
Installed in Junction Box‡
G*
N
L
Input
Output
V+
V-
CAT5 / Ethernet Cable (RJ45 Connections)
DMX Decoder
DMX Decoder
V- V+
V- V+
RGBW Tape Light / Fixture‡‡
V+ V+
CH1 R
CH2 G
CH3 B
CH4 W
V+ V+
CH1 R
CH2 G
CH3 B
Install applicable wire gauge / type
CH4 - W connection only utilized for RGBW / RGB(X) installation.
Wall Washer / DMX-512 Fixture‡‡
AC Power
50/60Hz
RJ45 / XLR-3
Adapter Connector
RGB Tape Light / Fixture‡‡
RJ45 Splice Cable
Wiring Connections
Brown Ground
White/Orange Data +
Orange Data -
White/Brown wire may be used as
an additional ground.
G
+
-
DMX Data
Output
RJ45 Coupler
DMX Controller
Installed in Wall Box‡
®
1 2 3
V+
V -
* Driver may not require a fault ground connection. Refer to driver specifications for additional information.
** Install a compatible Class 2 constant voltage driver. It is recommended to load the driver no more than 80% its labeled rating for maximum longevity.
‡ Refer to driver specifications for a compatible junction box.
‡‡ See luminaire specifications for maximum series run limits.