5 OF 5
®
Toll Free: 877.817.6028 | Fax: 415.592.1596 | www.DiodeLED.com | [email protected]
© 2019 Elemental LED Inc. All rights reserved. Specifications are subject to change without notice.
IG050919-4.0
DMX ZONE CONTROLLER
INSTALLATION GUIDE
TROUBLESHOOTING
For thorough troubleshooting of LED strip light and luminaires, see LED luminaire installation guides.
LED luminaires not responding to touch
1. Ensure the blue indicator light is on by pressing ‘Power.’ A red indicator signifies the device is off. The blue indicator light will blink rapidly when
pressing/holding any key on the touch pad.
2. Ensure the appropriate zone number was pressed prior to controlling the DMX decoder/luminaire. For example, if you know the luminaire is
addressed to zone 1, press ‘1’ prior to controlling.
3. Ensure the individual zone has not been turned off. Long pressing zones 1-3 will turn the specific zone ON/OFF. Additionally, long pressing R, G,
B, W will increase/decrease individual brightness and short pressing will turn R, G, B, W ON/OFF.
4. Ensure the DMX decoder/luminaire is addressed properly. For example, address ‘001’ will respond to zone 1 of the controller. See ‘Setting the
DMX Address’ for additional addressing information.
LED luminaire responding incorrectly
Ensure all wiring connections are correct. Reversing the Data + and Data - will cause lights to flicker and not respond to controller.
1. Check power connections of all components (drivers, DMX decoders/luminaires, DMX controller).
2. Check DMX Data connections - See
Pinout Connection Guide
and
System Diagram
for RJ45 hard-wiring connections.
3. Check DMX decoder connections –
See System Diagram
for CH 1-4 connections.
Visit the online product page at www.DiodeLED.com for additional product specifications & warranty information.
• DMX WALL MOUNT ZONE CONTROLLER SPECIFICATION SHEET
For full specifications.
• VOLTAGE DROP CHARTS
Use to specify appropriate wire gauge for installation. Available at the ‘Resources’ page at www.DiodeLED.com.
ADDITIONAL RESOURCES