4 Configurations on Web Interface
DAG1000-1S/2S/4S User Manual
Copyright©2011-2017 Dinstar
20
4.2.6
Record Statistics
On the
Status &
Statistic
Record Statistics
page, record statistics including server status,
count of current records, count of no response, count of server return errors, count of record
starts, count of record startAck, count of record stops and count of stopAck are displayed.
Figure 4-7 Record Statistics
4.3 Quick Setup Wizard
Quick setup wizard guides user to configure the device step by step. User only needs to
configure network, SIP server and SIP port in the Quick Setup Wizard interface. Basically,
after these three steps, user is able to make voice call via the DAG1000 device.
For the configurations of network
, SIP server and SIP port, please refer to 4.4 , 4.5 and 4.6 .
4.4 Network
4.4.1
Local Network
The DAG1000-1S/2S/4S device has two kinds of network mode: route and bridge. When the
device works under the route mode, it will work as a small router and NAT function is
enabled. Under this situation, WAN port is normally connected to router/switch or ADSL
MODEM, while LAN port is connected local computer or other network device (such as
Ethernet switches, Hubs etc.).
When the device works under the bridge mode, WAN port and LAN port are the same. The
device serves as a two-port Ethernet switch. Under this network mode, user only needs to
configure the IP address of WAN port and DNS.
Under the route mode, the default IP address of WAN port is a DHCP IP address, while the
default IP address of the LAN port is 192.168.11.1.