E-LW_01_14.03_EN_U
32
304 D.TIME
●
SECS
○
MINS
12.1.1.3 START UPON START-UP
If one of the inputs has not been linked to the “
ON/OFF
” function (
DOSAGE START/STOP
) and to the “
CONSENSUS
”
function, the dosage automatically starts right after the turn-on cycle of the instrument and it’s possible to stop it by
removing the power supply. In this case it is possible to clear the partial total also during the dosage.
12.1.2 PAUSE – MOMENTARY INTERRUPTION OF THE DOSAGE CYCLE
12.1.2.1 PAUSE THROUGH EXTERNAL INPUT
To pause the cycle, one has as first to configure an input as PAUSE function in the SETUP.
Then to pause the cycle in the weighing phase, press an instant the external button, which must be connected to the
previously configured input.
12.1.2.2 PAUSE THROUGH A CONFIGURABLE KEY
It is possible to pause the cycle through the function
306
combinable with the desired key (
<< F.KEYS >>
step,
TECH.MAN.REF.
).
12.1.3 DOSAGE CYCLE END MODE
12.1.3.1 DOSAGE END BY WEIGHT (DOSAGE TARGET)
The value of the weight that one wants to dose (target), must be programmed through the
F7
key or recalled together with
the article (see section ARTICLES DATABASE).
By setting a value different than zero, once the dosage is enabled, the instrument remains in this status until the
accumulated partial total surpasses the set target; once this threshold is surpassed, the instrument disables the dosage
output and enables the TARGET dosage output.
If the flight is foreseen, the instrument, while waiting the flight, totalizes the material until the flight time has passed. If the
flight time has been programmed at zero, the instrument ends the totalisation at the target.
It is anyway possible to end manually the dosage by disabling the cycle, but not by time: once the DOSAGE TARGET
WEIGHT is programmed, the indicator automatically clears the DOSAGE TIME.
12.1.3.2 DOSAGE END BY TIME
The value of the time until one wants to dose (target), must be programmed through the function
304
combinable with the
desired key (
<< F.KEYS >>
step,
TECH.MAN.REF.
).
By recalling the function one is asked as first to select the unit of measure of the entered value:
Select between SECS (seconds), MINS (minutes) and HOURS (hours) and press ENTER.
Then set the desired value and press ENTER to confirm.
By setting a value different than zero once the dosage is enabled, the instrument remains in this status until the set time is
over.
Once this time is surpassed, the instrument disables the dosage output and ends instantaneously the dosage.
It is anyway possible to end manually the dosage by disabling the cycle, but not by weight: Once the DOSAGE TARGET
TIME is programmed, the indicator automatically clears the DOSAGE WEIGHT.