VISUALISATION WITH ACTIVE FLOW-RATE ZOOM
The selectable info are shown on the single line under the “Weight”/ “Flow rate” section; by pressing the
F10
key (both
during and out of the dosage), one will scroll through the following visualisations in this order:
NUM.
SECOND LINE
VISUALISATION
OUT OF THE DOSAGE
DURING THE DOSAGE
0
Dosage status
1
(§)
Flow rate target
2
Partial total
3
In the dosage, remaining
material to be dosed or time to
elapse to end the dosage.
4
General total
5
Article total
(§) It can be displayed only if the flow regulator mode has been selected (F.Mode >> LoSS.W >> FUNC step,
TECH.MAN.REF.).
Out of the dosage, it is possible to quickly recall a visualisation by digiting, with the numeric keyboard, the relative number
and pressing the
F10
key.
Furthermore, by linking the number of a specific visualization to the function (preamble function in the
<< F.KEYS >>
step),
it is possible (both during and out of the dosage) to select it directly with a direct key, for example F1 key to select the
visualization n.1, and F2 key to select the visualization n. 2.
Notes:
- Default Visualisation: 0.
kg/h
DISABLED
kg/h
TRGT 20.0 kg/h
kg/h
P. T. 0.0 kg
kg/h
G. T. 0.0 kg
kg/h
A. T. 0.0 kg
kg/h
DOSAGE
kg/h
TRGT 20.0 kg/h
kg/h
P. T. 0.0 kg
kg/h
0.0 kg
kg/h
G. T. 0.0 kg
kg/h
A. T. 0.0 kg