5.5 SYSTEM STATUS INFO
Below there are the statuses shown on the display on the first line or the single line in the case of active zoom on CPWE.
MESSAGE
DESCRIPTION
DISABLED
The DOSAGE START input is OPEN. Also in this status, with flow greater than the
minimum, the instrument totalises the weight in transit, but the error checks are not
active.
WAITING
If a input is linked to consensus function, when the input is closed, the message will be
showed on the display and wait for the start command.
START
The instrument waits for the reaching of the hourly flow (<<tAr.tiM>> step
TECH.MAN.REF.
).
START DELAY
The instrument waits for the time set in the
<<dELAY>>
step before enabling the
dosage.
STOP DELAY
The instrument waits for the time set in the
<<dELAY>>
step before disabling the
dosage.
WAIT FOR FILLING
The instrument is in the filling phase.
LOCKED: FILLING
If
<<LOK.TIM>>
time has passed from when the filling has been enabled and the weight
is still the minimum filling threshold
<<StArt.W>>
, the display shows this message.
LOCK
Indicates that the dosage has stopped due to one of the following reasons:
- FLOW out of TOLERANCE RANGE
- WEIGHT LESS THAN MINIMUM or GREATER THAN MAXIMUM
PAUSE
The instrument is in the PAUSE status.
ALARM
The instrument is in the alarm condition, due one of the following reasons:
-
FLOW ALARM > MAX
:
FLOW out of TOLERANCE RANGE
-
WEIGHT ALARM > MAX
or
< MIN
: WEIGHT LESS THAN MINIMUM or GREATER
THAN MAXIMUM
DOSAGE
The instrument is in the dosage condition.
- OUT OF FLOW ! -
The instrument is in the underload or overload condition.
FLOW > MAX
The calculated flow is over
<<Max.F.r>>
.
UNLOAD SPEED (DAC)
The instrument has entered the MANUAL MATERIAL UNLOADING function (“
MANUAL
ENABLING OF THE DOSAGE OUT OF THE CYCLE, WITHOUT INCREMENT THE
TOTALS
”).
5.6 MESSAGES OF THE INSTRUMENT
While using the indicator, it is possible to incur the following errors:
INSIDE THE SET-UP OR MENU
MESSAGE
DESCRIPTION
Err.Mot.
The weight is unstable therefore it may not be acquired.
C.Er. – 38
C.Er. – 39
When carrying out the multirange or multidivisional calibration, the ranges have not been
entered in an increasing manner (RANGE 1 < RANGE 2 < RANGE 3).
C.Er. – 36
During the calibration some internal negative points have been calculated:
-
the calibration point is less than the zero point.
-
the signal is negative (check the connections)
C.Er. – 37
During the calibration some internal points less than the minimum value have been calculated:
-
the calibration point is equal to the zero point.
-
A capacity too high in relation to the division has been set.