7
Dingo D4040P User Guide
c.
Test the solar panel connection
by touching the negative (-)
wire from the solar panel onto
the Test terminal (TEST).
•If the alarm led does not flash
then it is OK.
•If the alarm led flashes quickly
then it is
not
OK. Check the
polarity and test again.
(There
must be some light on the solar
panels for this test to work).
If OK connect to the Solar
negative (-) terminal.
d.
Connect the negative (-) wire
from DC load circuit to the
load negative (-) terminal and
connect the positive wire from
the load to the load positve
(+) terminal. Test that the load
circuit works. The controller
is protected against load short
circuits, but cannot protect your
load devices if you reverse the
connection to them.
Now, set
the system voltage - see pg.10
Note: The controller is protected
against short circuit on the solar input.
Fig. 4
TEST
BOOST
V
+
-
+
-
+
-
Battery
+
–
flashes if
wrong
test
here
Test
Solar
2
Solar
–
+
TEST
BOOST
V
+
-
+
-
+
-
Battery
+
–
Solar
–
+
Connect
Load
3
Load
+
–