14
parameters you have set are all saved.
After finishing the temperature selection or temperature amendment, click
, then click
you will get the following interface:
Click ‘Start’
,the whole station starts to heating,and the working curve is showing
the current parameter
,
and it will also clear the previous curve showed on screen.The whole
heating will complete until the upper setting temperature or the upper part of the heating rate is
zero,and just the machine stops running,with the alarm ringing, if the cooling vacuum interface
has been set up within the cooling and vacuum state, then these two output also work.if click
‘stop’
in the normal operation process, the machine will stop heating.And click ’Keep’
, the button appears as flashing,showing the machine entering the temperature kept
status,and the whole heating temperature will keep the current temperature constant working,until
click the button again,it will return to normal heating.
Advanced Parameters have been set well, and they are not needed to change.The machine can
monitor the speed of the cooling fans, and also can set the lowest speed.When the cooling fans
stop running or the speed lower than the setting one, and the collection of hot air up and down the
value of the actual temperature is higher than 300 degrees, the heating system will stop heating
immediately. System can automatically set the early warning time, such as early warning: 10
second, showing that the buzzer alarm will sound when there is 10s left heating. When machine
into the cooling state, in the main interface will show the corresponding fault tips! It can help the
operator to quickly determine the point of failure!