Garantiebedingungen  und  Kundendienstadresse  siehe  Mon-
tage- und Gebrauchsanweisung Wärmepumpe.
For the terms of the guarantee and after-sales service addres-
ses, please refer to the Installation and Operating Instructions for
Heat Pumps.
Pour les conditions de garantie et les adresses SAV, se référer
aux instructions de montage et dútilisation de la pompe à cha-
leur.

Irrtümer und Änderungen vorbehalten.

Subject to alterations and errors.

Sous réserve d’erreurs et modifications.

Содержание VWU 65

Страница 1: ...utilisation Mat nr Zeich nr 98140404 3880 01 Bestell Nr Order no No de commande 452163 66 30 DE EN FR FD 9801 Externes 4 Wege Umschaltventil f r reversible W rmepumpe External 4 way reversing valve fo...

Страница 2: ......

Страница 3: ...3 Gesetzliche Vorschriften und Richtlinien DE 2 2 Lieferumfang DE 3 2 1 Allgemeine Beschreibung DE 3 2 2 Lieferumfang DE 3 3 Montage DE 4 3 1 Hydraulische Einbindung Vierwegeventil DE 4 3 2 Montagehin...

Страница 4: ...tlinien sind zu beachten ACHTUNG Wird ein doppelt differenzdruckloser Verteiler vorgesehen ist die Verdrahtung des R cklauff hlers gem siehe Bild 10 den Anweisungen vorzunehmen 1 2 Bestimmungsgem er G...

Страница 5: ...ib len W rmepumpe Die Umschaltung erfolgt ber einen elektro motorischen Stellantrieb der vom W rmepumpenmanager ange steuert wird 2 2 Lieferumfang Im Lieferumfang sind folgende Komponenten enthalten S...

Страница 6: ...ftung der Anschl sse Der Stellhebel muss im K hlen auf 0 und Heizen auf 1 stehen Die Hydraulik ist gem den bezeichneten Anschl ssen A B C und D vorzurichten Bild 2 zeigt die Beschriftung der Anschluss...

Страница 7: ...A B am W rmetauscher der W rmepumpe Bild 4 Schematische Ansicht Anschl sse W rmepumpe Aufkleber angebracht in W rmepumpe Bild 5 Exemplarische Ansicht hydraulischer Gesamtaufbau Beispiel ACHTUNG Es wi...

Страница 8: ...se ACHTUNG Vor Inbetriebnahme ist zu pr fen ob der Betriebsschalter auf Position 4 siehe Bild 7 steht Ein Nichtbeachten kann zu unerw nschten Betriebszust nden der W rmepumpe f hren ACHTUNG Alle Kompo...

Страница 9: ...plan Es wird empfohlen die Umschalteinrichtung m glichst nahe am W rmepumpenmanager zu montieren Die elektrische 3 adrige Zuleitung 2xL N zum Stellantrieb sollte eine L nge von maxi mal 40 m bei einem...

Страница 10: ...lus die Br cke A R2 zwischen X3 B2 und X3 1 entfernt und zwischen den Klemmen X3 1 und X3 2 wieder eingebaut werden Die R cklauftemperatur Rege lung wird in diesem Fall von dem Temperaturf hler R2 1 e...

Страница 11: ...ssen werden Bild 11 WPM Anzeige Vorkonfiguration 4 2 Technische Daten Bild 12 Druckverlustkennlinie Beschreibung Einstellbereich Anzeige Ist der Heizkreis mit oder ohne einem Vier Wege Ventil aufgebau...

Страница 12: ...DE 10 452163 66 30 FD 9801 Deutsch VWU 65 VWU 80...

Страница 13: ...egal regulations and directives EN 2 2 Scope of supply EN 3 2 1 General description EN 3 2 2 Scope of supply EN 3 3 Installation EN 4 3 1 Hydraulic integration of four way valve EN 4 3 2 Installation...

Страница 14: ...be carried out by authorised persons The applicable regulations must be observed ATTENTION If a dual differential pressureless manifold is to be used the return sensor must be wired according to the...

Страница 15: ...oth heating and cooling Reversing is carried out by an electromotive actuator which is activated by the heat pump manager 2 2 Scope of supply The following components are included in the scope of supp...

Страница 16: ...The control lever must be positioned 0 for cooling and 1 for heating The hydraulics must be arranged in accordance with the designated connections A B C and D Fig 2 shows the labelling of the connect...

Страница 17: ...nnections A B on the heat exchanger of the heat pump Fig 4 Schematic view heat pump connections label affixed inside the heat pump Fig 5 Sample view of complete hydraulic assembly example ATTENTION Pr...

Страница 18: ...pplementary notes ATTENTION Before start up always ensure that the operating switch is in position 4 see Fig 7 Undesired changes to the heat pump s operating state may result if this is not observed A...

Страница 19: ...ur way valve Connection diagram We recommend installing the reversing valve as close to the heat pump manager as possible The 3 core electrical supply cable 2xL N to the actuator should not exceed a m...

Страница 20: ...etween X3 B2 and X3 1 and re inserted between terminals X3 1 and X3 2 In this case the return temperature reg ulation is measured by temperature sensor R2 1 which is lo cated in the dual differential...

Страница 21: ...p manager display Pre configuration 4 2 Technical data Fig 12 Pressure loss characteristic curve Description Setting range Display Is the heating circuit constructed with or without a four way valve I...

Страница 22: ...EN 10 452163 66 30 FD 9801 English VWU 65 VWU 80...

Страница 23: ...spositions l gales et directives FR 2 2 Fournitures FR 3 2 1 G n ralit s FR 3 2 2 Fournitures FR 3 3 Montage FR 4 3 1 Int gration hydraulique vanne 4 voies FR 4 3 2 Remarques de montage vanne et organ...

Страница 24: ...utoris Respecter les directives correspondantes ATTENTION Si un distributeur double sans pression diff rentielle est pr vu le c blage de la sonde sur circuit de retour doit tre effectu selon les instr...

Страница 25: ...pompe chaleur r versible La commutation s effectue via un organe moteur lectrique command par le gestionnaire de pompe chaleur 2 2 Fournitures Les composants suivants font partie des fournitures Organ...

Страница 26: ...levier de commande doit tre positionn sur 0 pour le rafra chissement et 1 pour le chauffage L hydraulique doit tre pr par e selon les raccordements d crits A B C et D La Figure 2 montre les raccordem...

Страница 27: ...l changeur thermique de la pompe chaleur Figure 4 Vue sch matique Raccordements pompe chaleur autocollant appos dans la pompe chaleur Figure 5 Exemple d une structure hydraulique globale ATTENTION Il...

Страница 28: ...Avant la mise en service v rifier que le commutateur de service soit sur la position 4 voir Figure 7 Le non respect de cette consigne engendre des d fauts de fonctionnement de la pompe chaleur ATTENTI...

Страница 29: ...bornes Il est recommand de monter la vanne d inversion proximit imm diate du gestionnaire de pompe chaleur La ligne d ali mentation lectrique 3fils 2xL N vers l organe moteur ne doit pas d passer une...

Страница 30: ...entre X3 B2 et X3 1 doit tre retir et r install entre les bornes X3 1 et X3 2 La r gulation de la temp rature de retour est dans ce cas mesur e par la sonde de temp rature R2 1 situ e dans du distrib...

Страница 31: ...stionnaire Pr configuration 4 2 Caract ristiques techniques Figure 12 Caract ristique de perte de pression Description Plage de r glage Affichage ILe circuit de chauffage est il con u avec ou sans van...

Страница 32: ...ales service addres ses please refer to the Installation and Operating Instructions for Heat Pumps Pour les conditions de garantie et les adresses SAV se r f rer aux instructions de montage et d tilis...