Dimplex SCx175sd Скачать руководство пользователя страница 14

 

14

 

12.2

. The flow temperature of the hot water can be set to your requirements on the immersion heater 

ideally  60

°

C. Higher temperatures can cause tripping of the high limit thermostat and introduces more 

energy loss from the cylinder. 
 

12.3

. When a hot tap is turned on there may be a short surge of water, this is quite normal with 

unvented systems and does not mean there is a fault. 

 
12.4.

 When you first fill a basin the water may sometimes appear milky. This is due to very tiny air 

bubbles in the water which will clear very quickly. 
 

12.5.

 

WARNING:

 If cold/warm water exits from the temperature and pressure relief valve (TPV) or 

from the pressure relief valve call your installer or the Dimplex customer service centre. If very hot 
water exits from either valve switch off the heat source immediately and isolate the electricity supply 
to the cylinder and separate heat source. 
 

12.6 

The solar system is configured to heat the water to its maximum economic temperature which 

may vary with outside temperature and weather conditions. The immersion or boiler may be 
programmed to operate during fixed periods of the day or night. If the hot water runs cool it may be 
necessary to manually switch on the immersion or boiler to heat the water.

 

 

 

13  Warranty 

 

13.1.

 Dimplex UK Limited guarantee all electrical and mechanical controls supplied with  the cylinder, 

excluding the immersion, for a period of 5 years from the date of purchase provided that they have 
been installed for their intended use by a competent person and have not been modified in any way. 
The immersion(s) are guaranteed for a period of 2 years, excluding any failure caused by limescale. 
 

13.2.

 In addition Dimplex UK Limited guarantees the stainless steel inner hot water cylinder for a 

period of 25 years from the date of purchase against faulty material or manufacture provided that: 

(a)  It has been installed by a competent person in accordance with this installation manual and all 

current regulations and codes of practice at the time of installation. 

(b)  It has been used solely for the purpose of heating potable water that complies with current (at 

the time of installation) EU standards and is not fed with water from a private source.  

(c)  It has not been modified in any way. 
(d)  It has not been subjected to excessive pressure or electrolytic action from dissimilar materials, 

or attack from any salt deposits. 

(e)  It has been installed indoors in a frost-free environment. 
(f)  The cylinder is connected to a public water supply maintained by a local water authority. 
(g) The warranty card is completed and returned to  Dimplex UK Limited within 90 days of 

installation. 

This warranty is not transferable. This warranty does not include claims due to frost or lime scale 
damage. Proof of purchase will be required against any claim.  This guarantee does not affect your 
statutory rights. 

Содержание SCx175sd

Страница 1: ...SOLAR UNVENTED WATER HEATERS Installation and Operation Manual Important This Manual Should Be Left With The Cylinder After Installation...

Страница 2: ...quirements 5 5 Primary circuit installation 6 6 Secondary circuit installation 6 7 Discharge arrangement 8 8 Electrical installation 10 9 Filling and commissioning 11 10 Servicing and maintenance 12 1...

Страница 3: ...42 542 542 542 542 542 Solar Return mm 380 380 380 380 380 380 380 380 Cold Inlet mm 300 300 300 300 300 300 300 300 solar Coil size sqm 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Aux Coil size sqm 0 75 0 75 0 7...

Страница 4: ...4 2 2 Connection 2 2 1 SOLAR Indirect 2 2 2 Single Coil Direct Electric...

Страница 5: ...it to function but flow from the outlets will be low if several outlets are used simultaneously Correct performance is achieved with supplies between 3bar and 12bar The cylinder control equipment is f...

Страница 6: ...nce with the solar installation instructions for connection to the primary flow and return 5 3 Two port Motorised valves The SCx Solar range of cylinders must only be connected to solar installations...

Страница 7: ...ve should be connected to the secondary return of the cylinder See fig 4 1 4 2 IMPORTANT If a secondary circulation circuit is installed then a larger expansion vessel may be required to handle the in...

Страница 8: ...lity at one or other of these locations Examples of acceptable discharge arrangements are Ideally below a fixed grating and above the water seal in a trapped gully Downward discharge at low level i e...

Страница 9: ...diameter temperature relief valve with a discharge pipe D2 having 4 elbows and a length of 7m from the tundish to the point of discharge From the table above the maximum resistance allowed for a strai...

Страница 10: ...the following should also be observed 8 2 1 Ensure the mains voltage corresponds to the voltage rating of the immersion heater as shown on the rating label on the terminal cover 8 2 2 Insert the imme...

Страница 11: ...3 8 4 The Power Supply to the pump station should be connected via the lower 9 Filling and commissioning 9 1 Check that the expansion vessel charge pressure is 3bar 9 2 Check that all connections are...

Страница 12: ...k that the immersion or boiler switches off when the cylinder reaches the desired temperature 10 Servicing and maintenance 10 1 Servicing and maintenance must only be carried out by a competent unvent...

Страница 13: ...ked 3 Pressure reducing valve PRV fitted the wrong way 1 Open stopcock 2 Turn water supply off remove strainer and clean see 10 6 3 Re fit with arrow pointing in direction of flow Water from hot taps...

Страница 14: ...ntrols supplied with the cylinder excluding the immersion for a period of 5 years from the date of purchase provided that they have been installed for their intended use by a competent person and have...

Страница 15: ...m straight tundish SC06004 3kW Immersion heater SC070011 or SC070012 22mm Pressure reducing valve kit SC07015 22mm 2 port motorised valve SC06005 Twin Cylinder Thermostat SC06006 For assistance please...

Страница 16: ...f practice It is recommended that your hot water system is serviced regularly and that your service engineer completes the appropriate Service Interval Record below SERVICE 1 DATE SERVICE 2 DATE ENGIN...

Отзывы: