Dimplex SCx175sd Скачать руководство пользователя страница 11

 

11

8.3 

Two Port Valve

-The two port valve should be wired to the twin thermostat as per Figure 8.2 

below: 

 
8.3.1   Connect the Live supply to the thermal-cut-out and connect the brown wire of the two-port 

valve to terminal 2 on the thermostat. Earth and Neutral supplies can be connected directly to 
the valve. 

 
8.3.2  The orange wire of the two-port valve should be connected to the central heating boiler. 
 
8.3.3  The cylinder thermostat should be set to 60

o

 

 
 
 
 
 
 
 
 
 
 

Fig 8.2 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig 8.3 
 
8.4 

The Power Supply to the pump station should be connected via the lower  

 

9. Filling and commissioning 

 

9.1.

 Check that the expansion vessel charge pressure is 3bar. 

 

9.2.

 Check that all connections are tight and correctly configured. 

 

9.3.

 Open the main stopcock and fill the secondary system. Open successive hot taps. Leave each 

tap open for a few minutes to allow all air and debris from the system to exit. Close all taps. 
 

Thermostat

L

N

E

1

2

3

4

5

6

7

8

9 10

X

X

X

X

X

X

X

Thermal cut-out

C

E 1

2

Solar Circulating Pump 230 V supply?

Thermostat

Bn

Bl G/Y

O

G

L

N

E

1

2

3

4

5

6

7

8

9 10

X

X

X

X

X X

X

Thermal cut-out

C

E 1

2

Two-port motorised valve

Boiler switched live

Содержание SCx175sd

Страница 1: ...SOLAR UNVENTED WATER HEATERS Installation and Operation Manual Important This Manual Should Be Left With The Cylinder After Installation...

Страница 2: ...quirements 5 5 Primary circuit installation 6 6 Secondary circuit installation 6 7 Discharge arrangement 8 8 Electrical installation 10 9 Filling and commissioning 11 10 Servicing and maintenance 12 1...

Страница 3: ...42 542 542 542 542 542 Solar Return mm 380 380 380 380 380 380 380 380 Cold Inlet mm 300 300 300 300 300 300 300 300 solar Coil size sqm 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Aux Coil size sqm 0 75 0 75 0 7...

Страница 4: ...4 2 2 Connection 2 2 1 SOLAR Indirect 2 2 2 Single Coil Direct Electric...

Страница 5: ...it to function but flow from the outlets will be low if several outlets are used simultaneously Correct performance is achieved with supplies between 3bar and 12bar The cylinder control equipment is f...

Страница 6: ...nce with the solar installation instructions for connection to the primary flow and return 5 3 Two port Motorised valves The SCx Solar range of cylinders must only be connected to solar installations...

Страница 7: ...ve should be connected to the secondary return of the cylinder See fig 4 1 4 2 IMPORTANT If a secondary circulation circuit is installed then a larger expansion vessel may be required to handle the in...

Страница 8: ...lity at one or other of these locations Examples of acceptable discharge arrangements are Ideally below a fixed grating and above the water seal in a trapped gully Downward discharge at low level i e...

Страница 9: ...diameter temperature relief valve with a discharge pipe D2 having 4 elbows and a length of 7m from the tundish to the point of discharge From the table above the maximum resistance allowed for a strai...

Страница 10: ...the following should also be observed 8 2 1 Ensure the mains voltage corresponds to the voltage rating of the immersion heater as shown on the rating label on the terminal cover 8 2 2 Insert the imme...

Страница 11: ...3 8 4 The Power Supply to the pump station should be connected via the lower 9 Filling and commissioning 9 1 Check that the expansion vessel charge pressure is 3bar 9 2 Check that all connections are...

Страница 12: ...k that the immersion or boiler switches off when the cylinder reaches the desired temperature 10 Servicing and maintenance 10 1 Servicing and maintenance must only be carried out by a competent unvent...

Страница 13: ...ked 3 Pressure reducing valve PRV fitted the wrong way 1 Open stopcock 2 Turn water supply off remove strainer and clean see 10 6 3 Re fit with arrow pointing in direction of flow Water from hot taps...

Страница 14: ...ntrols supplied with the cylinder excluding the immersion for a period of 5 years from the date of purchase provided that they have been installed for their intended use by a competent person and have...

Страница 15: ...m straight tundish SC06004 3kW Immersion heater SC070011 or SC070012 22mm Pressure reducing valve kit SC07015 22mm 2 port motorised valve SC06005 Twin Cylinder Thermostat SC06006 For assistance please...

Страница 16: ...f practice It is recommended that your hot water system is serviced regularly and that your service engineer completes the appropriate Service Interval Record below SERVICE 1 DATE SERVICE 2 DATE ENGIN...

Отзывы: