Energy Related Product Directive

Model Identifier(s):

PLX050E PLX075E PLX100E PLX125E PLX150E PLX200E PLXC300E

Height (mm)

430

430

430

430

430

430

430

Width (mm)

450

620

620

690

690

860

860

Depth (mm)

108

108

108

108

108

108

143

Technical Details

Product information according to Ecodesign Regulation (EU) 2015/1188

Model Identifier(s):

PLX050E PLX075E PLX100E PLX125E PLX150E PLX200E PLXC300E

Heat Output

Nominal heat output

Pnom

0.50kW

0.75kW

1.00kW

1.25kW

1.50kW

2.00kW

3.00kW

Minimum heat output 

(indicative)

Pmin

N.A

N.A 

N.A

N.A

N.A

N.A

N.A

Maximum heat output

Pmax,c

0.50kW

0.75kW

1.00kW

1.25kW

1.50kW

2.00kW

3.00kW

Auxiliary electricity consumption 

At nominal heat output

elmax

0.00

0.00

0.00

0.00

0.00

0.00

0.00

At minimum heat output

elmin

0.00

0.00

0.00

0.00

0.00

0.00

0.00

In standby mode

elSB

<0.0005

<0.0005

<0.0005

<0.0005

<0.0005

<0.0005

<0.0005

Type of heat output / room temperature control 

Electronic heat charge control with 

room and / or outdoor temperature 

feedback

Yes

Other control options

Room temperature control, with 

open window detection

Yes

With adaptive start control

Yes

Contact details

Glen Dimplex Heating and Ventilation
Millbrook House, Grange Drive, Hedge End, Southampton, SO30 2DF
Tel: 0344 879 3588
This product meets the Ecodesign requirements for an electric storage local space heater. Commission 
Regulation (EU) 2015/1188.

Содержание PLX050E

Страница 1: ...INSTRUCTION MANUAL Installation and Operating 08 54284 0 ISSUE 1 Series B PLXE Panel Heater Models PLX050E PLX075E PLX100E PLX125E PLX150E PLX200E PLXC300E Note PLXC300E features a slotted grille...

Страница 2: ...top of the heater or the air inlet slots in the base of the heater The heater carries a warning DO NOT COVER to alert the user to the risk of fire that exists if the heater is accidentally covered CAU...

Страница 3: ...s mains lead are coloured in accordance with the following code GREEN AND YELLOW EARTH BLUE NEUTRAL BROWN LIVE The heater is fitted with a length of flexible cable type H05VV F size 3 x 1 0mm2 for con...

Страница 4: ...I E E Wiring Regulations Please note that lit cigarettes candles and oil burners combined with the convection effect of electric heaters can cause soot deposits to build up on the surface directly abo...

Страница 5: ...4...

Страница 6: ...W 0 75kW 1 00kW 1 25kW 1 50kW 2 00kW 3 00kW Auxiliary electricity consumption At nominal heat output elmax 0 00 0 00 0 00 0 00 0 00 0 00 0 00 At minimum heat output elmin 0 00 0 00 0 00 0 00 0 00 0 00...

Страница 7: ...powder coated steel casing with louvered forward facing grille Advanced controls with capacitive sense technology for total flexibility of heating Note PLXC300E features a slotted grille Element Compa...

Страница 8: ...hat stated on the heater General Wall Mounting IMPORTANT The wall bracket supplied with the heater must be used and the heater must be installed in the correct orientation The fixings should be used t...

Страница 9: ...type 3 Present the heater to the wall bracket and engage bottom slots in the back with bracket hooks 4 Press heater into locked position and ensure the clips on the top are engaged 5 Remove protectiv...

Страница 10: ...he Heaters controls refer to page 11 The Heater will then take the User to the Home Screen with the Out All Day Timer Mode active First Time Power On Important During initial heat up some odour may be...

Страница 11: ...mplex Control on your device s app store Requires additional hardware Sold seperately Visit Dimplex co uk for more information A Dimplex Hub is required for this product to connect to Dimplex Control...

Страница 12: ...perature and is normal for this type of product Whilst the noise produced is usually very quiet certain environmental factors can make it more noticeable such as hard flooring or minimal furnishings I...

Страница 13: ...isplayed in a manual mode of operation When the controller buttons have not been pressed for a long period of time the display will sleep and the text will disappear The heater is still on and active...

Страница 14: ...et Temperature of a Heating On period when that period is active This will temporarily adjust the Target Temperature for just that instance and will not permanently modify the settings for the timer i...

Страница 15: ...Preview This option displays the timer s configuration This is handy to quickly check the timer without being able to change any values ADVANCE MENU BACK ENTER Manual 21 C Period 1 Period 2 Period 3 P...

Страница 16: ...py Paste To save time when modifying a Timer Mode the Advance button can be used to copy and paste settings Individual heating periods from one day or every heating period from a day can be copied to...

Страница 17: ...and no date is set Away Mode will count from either the current time or if a date is set Away Mode The Advance button is only used when a Timer Mode is active and allows the timer schedule to be chan...

Страница 18: ...Temperature value Manual Default 21 C Can be changed from the Home Screen to any value within the Heater s Temperature Range Eco Default 19 C Can be changed from the Home Screen to any value in the H...

Страница 19: ...s Target Temperature Range setting The Boost Time can be increased in the following increments 30 mins 1 hour 2 hours 3 hours 4 hours These increments can be restricted with the Max Boost Duration Ran...

Страница 20: ...choose to unlock the heater if they wish to change the temperature modes or settings Heater Lock PIN Lock Heater Lock is the most customisable and secure lock on the heater This allows the heater to...

Страница 21: ...Disabled during UI lock the Advance button will not function Boost Function Operation during PIN Lock If enabled Boost will function in the same way as it does when PIN Lock is not active unless modi...

Страница 22: ...ell as enable disable modification of the Boost Temperature and Boost Duration See below Boost Lock Three settings can be modified within this Menu Enable Disable The Boost Menu Item can be Enabled Di...

Страница 23: ...boost is activated Boost Settings Setback Settings Setback is a function that only modifies Timer Mode operation When Setback is enabled it overrides any Heating Off period to maintain a constant tem...

Страница 24: ...n This is a global setting that can interrupt any active mode Activating this setting enables Open Window Detection to switch the Heater to a Heating Off state if it detects an open window in the room...

Страница 25: ...ttons for 5 seconds Each of the following headings relate to an item in the settings menu Temperature Settings Temp Units Temperature Units This setting defines which temperature units are displayed o...

Страница 26: ...t Code Description 20 Component thermistor hardware fault 21 22 23 24 30 Component overheat 32 33 34 40 Internal serial comms error 41 Heating element fault 50 Open window detected 52 Heat output disa...

Страница 27: ...26...

Страница 28: ...ig 2 page 7 and locate the battery module 2 Slide the catch and pull module from the controls 3 Remove the coin cell battery and replace 4 Slide module back in place ensuring clip is engaged IMPORTANT...

Страница 29: ...om the wall using the clips shown in Fig 2 page 7 and locate the battery module indicated in Fig 5 2 Slide the catch and pull module from the controls See Fig 5 1 3 3 Replace the tray with the radio f...

Страница 30: ...by this Dimplex Guarantee there may be a charge to repair your product However we will contact you for agreement to any charges before any chargeable service is carried out What is not covered by a Di...

Страница 31: ...art the two year Guarantee Period afresh from the date of delivery of the replacement Dimplex product to you The Dimplex Guarantee does not entitle you to recovery of any indirect or consequential los...

Страница 32: ...h the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 9...

Отзывы: