h
5.2
Fig. 3.2:LIA 12IM / LIA 14IM / LIA 16IM basic device
1)
Indoor unit main circuit board
2)
Control panel
3)
Pressure relief valve
4)
Flow switch
5)
Pressure gauge
6)
Circulating pump
7)
RCCB (3 units)
8)
Overload protection (3 units)
9)
Pipe heater
10) Expansion vessel
4 Accessories
NOTE
Use the accessory components supplied and the prescribed parts for
installation.
5 Installation
5.1 General
ATTENTION!
Install the device in a location that is capable of withstanding the weight
of the system.
The following connections need to be established on the heat
pump:
Flow and return of the refrigerant pipe
Flow for heating and domestic hot water preparation
Joint return for heating and domestic hot water preparation
Outflows for the pressure relief valves
Condensate drain
Power supply
Temperature sensor
5.2 Indoor unit installation
Fig. 5.1:Indoor unit installation
ATTENTION!
If the indoor unit is mounted 4 or more metres higher than the outdoor
unit, a cooling technology specialist must perform a separate check to
ensure that the devices for conveying the oil up and down the pipes have
been installed correctly in the hot gas pipe.
Do not install any heat source in the vicinity of the device.
Ensure that there is a good circulation of air inside the room.
The noise which will be generated in the room should be
taken into account.
The minimum distances marked by arrows must be
maintained.
The device must be installed on the wall vertically.
The device must be mounted in a room which is free of frost.
No.
Accessory component
Quantit
y
1
Mounting plate
1
2
Drain elbow
1
3
Cable tie
3
4
Protective ring
2
5
Screws
3
6
Mounting plate
1
FP
RU
PRUH
FP
RU
PRUH
FP
RU
PRUH
FP
RU
PRUH
%DVH