Step 3: Orientate the sensor mounting plate to allow access to the phials (four clips in the centre of the
sensor mounting plate). Be careful not to kink the capillaries that connect the thermostat bulbs. The
sensor mounting plate will have two vacant slots for additional sensors (D). Repeat for both positions.
Step 4: Move the sensor mounting plate back into its fixing position. Be careful not to kink the capillaries
that connect the thermostat bulbs. Fit the four M5 fixing screws into the cylinder bracket (E). Tighten
the screws until the thermostat bulbs and heat pump sensor are held firmly against the wall of the inner
cylinder. Repeat for both positions.
Note: there should be no movement in the phials that are used to hold the bulbs and sensor. Care should
be taken not to overtighten the screws.