Free Standing/Portable Use 

 
The heater may be used free standing in either the 
upright or lay-flat position as shown The heater 
incorporates a permanently fixed wall mounting bracket 
for use when the heater is installed as a fixed appliance, 
and which acts as a stand when in either position. 
Reference should be made to the section “Heater 
Dimensions and Minimum Operating Distances” before 
use 
 

WARNING 

-  

IF THE HEATER IS FREE 

STANDING IT MUST NOT BE USED IN THE 
IMMEDIATE SURROUNDINGS OF A BATH

SHOWER OR A SWIMMING POOL 
 

 
 
 
 
FIXING THE HEATER 

 

 
The heater may be fixed to the wall or floor using 
the fixing holes provided in the mounting frame. Please 
refer to the Section “Heater Dimensions and Minimum 
Operating Distances” before fixing the heater in position 
 
 
 
 
 

Fixing to the Wall  
 

WARNING - The heater must NOT be located 
immediately below a fixed socket outlet 

 

The heater must be fixed only in the upright position 
with the control panel at the bottom. The position of the 
two upper fixing points should first be marked on the 
wall, at a horizontal distance of 100mm apart, Diagram 
A. Place the heater in position with the upper wall 
bracket notches against these fixing points to check that 
the heater complies with the “minimum operating 
distances”. These two fixing points should then be 
drilled and plugged. Suitable round headed size 8 
screws should be fixed in these positions to such a 
depth that the heater may be hung in position while the 
positions of the lower fixing holes are marked, Diagram 
B. The heater should then be removed while the lower 
fixing holes are drilled and plugged. Then the heater 
should be hung in position on the upper two screws 
while the lower two screws are tightened to hold the 
heater firmly on the wall. The tightness of the upper 
screws should be adjusted if necessary to ensure a firm 
fit. 
 
 
 
 
 

Fixing to the Floor 
 

The heater may be fixed to the floor in the lay-flat 
position. Before fixing the heater in position place it in 
the desired position and check that it complies with the 
requirements described in the section “Heater 
Dimensions and Minimum Operating Distances”. 
For guidance on fixing the heater see the section on 
‘Fixing to the Wall”. The principles involved are the 
same. 
 

 
 
 

 
 