9
Fireplace Installation
For 120V Installations
Use two conductor, non-metallic
sheath cable with ground wire (3
wires total) for the incoming power
supply.
CAUTION:
Use the appropriate
wire to meet local and national
electrical codes for rated power
consumption.
•
Connect the L1 wire from the unit
to the live wire from the power
supply.
•
Connect the N and H1 wires from
the unit to the neutral wire from
the power supply.
•
Connect the L2 and H2 wires
together, with a wire connector
and leave them disconnected
from everything.
•
Attach the grounding wire to
the cover with the provided
grounding screw. Place wire in-
between screw and lock washer
and tighten (Figure 4).
•
Reposition the electrical cover
brackets over the wires and
connectors and attach to
fireplace chassis using the screw
removed in step 1 and step 3.
Figure 4
Hole for
Ground Screw
Figure 3