22
DOK4SVxxDEN · FD 9912
www.glendimplex.de
English
Domestic ventilation unit M Flex Air (Plus)
8.2 Operating modes
The ventilation unit has 3 fan speeds. The following operating
modes can be selected:
Fig. 8.3:Operating modes
The operating mode is set in the basic display on the ventilation
unit control unit using the
and
keys.
Pressing the OK key in the basic display opens or closes the by-
pass. The manual bypass control depends on the configuration
and may not be activated (see User menu under 20 - Settings).
OFF
The fans in the ventilation unit are switched off (depending
on the unit configuration, setting may not be available or
may be configured differently)
AUTOMATIC
Demand-based control of the ventilation unit using air
quality sensors enables extremely economical operation. In
automatic mode, the volume flow is regulated continu-
ously depending on the exhaust air quality. The speed of
the fans is increased at higher ventilation requirements.
With low ventilation requirements, the fans run at low
speeds in energy-saving mode.
If the outside air quality is poor, the additional integrated air
quality sensor in the outside air enables automatic mode to
adjust to low speeds to guarantee continued moisture pro-
tection but to ensure that only a small proportion of the
poor outside air is brought into the building.
SPEED 1
(Reduced ventilation)
Basic ventilation to prevent moisture damage, e.g. during
periods of absence or at night.
SPEED 2
(Normal ventilation)
Normal operation when people are present, e.g. during the
day.
SPEED 3
(Intensive ventilation)
Shock ventilation during temporary extremely high ventila-
tion requirements to combat load peaks, e.g. when cook-
ing, taking a shower or bath, smoking or if large numbers of
people are present.
8.3 User menu
The user menu is used to set weekly timer programs and oper-
ating parameters (filter signal, bypass, external units and sen-
sors) and displays information on the status and operation of
the ventilation unit (fan speed,volume flows, temperatures,
input/output status, error history).
Access: Press the and
OK
keys simultaneously for
5 sec
Fig. 8.4:User menu
The user menu is indicated in the top left of the display by the
symbol.
HINWEIS
ºº
º
ºº
º
NOTE
A detailed description of the user menu can be found in the
operating instructions.
Programs
Activation times can be programmed for every day of the week.
First select the day of the week, then set the activation time
with the hour and minute and then select the operating mode
to be activated.
Setting the clock
The ventilation unit is equipped with a real time clock with cal-
endar function. If the day of the week or time is incorrect, the
time can be set again.
First set the current date (day, month, year). The day of the
week is determined automatically by the calendar function.
Then set the time (hour, minute).
HINWEIS
ºº
º
ºº
º
NOTE
Changing between summer/winter time takes place automat-
ically if the power supply is switched on.
In the event of a power failure, the real time clock continues
running with a buffer battery. The set time is retained.
Operating mode
Application
OFF
1
1. May not be available depending on the unit configuration
Ventilation unit should always be in operation
(moisture protection, including during long peri-
ods of absence)
AUTOMATIC
Minimum operation for moisture protection,
automatic continuous air volume regulation
if air quality sensor connected
SPEED 1
Reduced ventilation
(e.g. at night or during periods of absence)
SPEED 2
Normal ventilation
(normal operation when people are present dur-
ing the day)
SPEED 3
Intensive ventilation
(e.g. shock ventilation or party mode)
5 sec.
+
OK
d
Bedienermenü
40 Languages
d
Bedienermenü
30 Information
d
Bedienermenü
20 Settings
Bedienermenü
10 Timer & Uhr