8.7 Error codes
No.
Format
Meaning
203
@E203
Wrong syntax in command, prohibited parameter in command entry or non-valid result
210
@E210
Not in tracking mode, start tracking mode first
211
@E211
Sampling too fast, set the sampling time to a larger value
212
@E212
Command cannot be executed, because tracking mode is active, first use command sNc to stop tracking
mode
220
@E220
Communication error
230
@E230
Distance value overflow caused by wrong user configuration. Change user offset (and/or user gain)
231
@E231
Wrong mode for digital input status read
232
@E232
Digital output 1 cannot be set if configured as digital input
233
@E233
Number cannot be displayed. (Check output format)
234
@E234
Distance out of range
236
@E236
Digital output manual mode (DOM) cannot be activated when configured as digital input
252
@E252
Temperature too high
(contact Dimetix if error occurs at room temperature)
253
@E253
Temperature too low
(contact Dimetix if error occurs at room temperature)
254
@E254
Bad signal from target
It takes too long to measure according distance
255
@E255
Received signal too weak
(Use different target and distances, if the problem persists, please contact Dimetix)
256
@E256
Received signal too strong
(Use different target and distances, if the problem persists, please contact Dimetix)
257
@E257
Too much background light
(Use different target and distances, if the problem persists, please contact Dimetix)
258
@E258
Power supply voltage is too high
260
@E260
Distance cannot be calculated because of ambiguous targets. Use clearly defined targets to measure the
distance.
360
@E360
Configured measuring time is too short
361
@E361
Configured measuring time is too long
not listed
Hardware failure (Contact Dimetix)
Before contacting Dimetix, please collect as much information as possible.