T
ECHNICAL
R
EFERENCE
M
ANUAL
8.3.3 Set automatic mode (s
N
A)
This command activates the automatic mode of the DLS-C(H)/FLS-C(H). It triggers continuous measurement of the distance. The analog,
digital and SSI outputs are updated according to the measured distance values. The sampling time defines the measurement rate. If the
sampling time is set to zero, the measurements are executed as fast as possible (depending on target conditions).
The automatic mode is active until the STOP/CLEAR command (
s
N
c
') is issued.
The operating mode is stored in the DLS-C(H)/FLS-C(H) and activated immediately. This mode is also
activated after next power ON.
Internally, “tracking with buffering” is started (command
sNf
). Therefore, the last measurement can
also be read out from the module with the command
sNq
.
Command
Command
s
N
A+
xxxxxxxx
<trm>
Return successful
g
N
A?<trm>
Return Error
g
N
@E
zzz<trm>
Parameters
N
Module number (0..9)
xxxxxxxx
Sampling time in 10 ms (if 0 -> max. possible rate)
zzz
Error code
8.3.4 Set/Get analog output min level (s
N
vm)
This command sets the minimum analog output current level (0 or 4 mA).
Set Command
Get Command
Command
s
N
vm+
x
<trm>
s
N
vm<trm>
Return successful
g
N
vm?<trm>
g
N
vm+
x
<trm>
Return Error
g
N
@Ezzz<trm>
g
N
@E
zzz<trm>
Parameters
N
Module number (0..9)
x
Minimum output for analog out
0: Minimum current is 0 mA
1: Minimum current is 4 mA
zzz
Error code
Configuration parameters need to be saved (See 8.3.8 Save configuration parameters (sNs) on page 28)
8.3.5 Set/Get analog output value in error case (s
N
ve)
This command sets the analog output current level in mA in case of an error. This level can be lower than the minimum level set in
8.3.4
Set/Get analog output min level (sNvm)
.
Set Command
Get Command
Command
s
N
ve+xxx<trm>
s
N
ve<trm>
Return successful
g
N
ve?<trm>
s
N
ve+
xxx
<<trm>
Return Error
g
N
@Ezzz<trm>
g
N
@E
zzz<trm>
Parameters
N
Module number (0..9)
xxx
Value in case of an error in 0.1mA
zzz
Error code
Configuration parameters need to be saved (See 8.3.8 Save configuration parameters (sNs) on page 28)