4.2 Specifications
Typical measuring accuracy for
DLS-C 15 / DLS-CH 15
1)
DLS-C 30 / DLS-CH 30
1)
FLS-C 10 / FLS-CH 10
1,3)
FLS-C 30 / FLS-CH 30
1,3)
± 1.5 mm @ 2
σ
± 3.0 mm @ 2
σ
± 1.0 mm @ 2
σ
± 3.0 mm @ 2
σ
Accuracy of the analog output
DLS-C(H)
FLS-C(H)
0.2% programmed span (8.3.6 Set/Get distance range (sNv) on page 27)
0.1% programmed span (8.3.6 Set/Get distance range (sNv) on page 27)
Typical Repeatability for
DLS-C 15 / DLS-CH 15
1)
DLS-C 30 / DLS-CH 30
1)
FLS-C 10 / FLS-CH 10
1)
FLS-C 30 / FLS-CH 30
1)
± 0.4 mm @ 2
σ
± 0.5 mm @ 2
σ
± 0.3 mm @ 2
σ
± 0.5 mm @ 2
σ
Smallest unit displayed
0.1 mm
Measuring range on natural surfaces
0.05 m to approx. 65 m
Measuring range on orange (reflective) target plate DLS-C(H)
FLS-C(H)
Approx. 25 m to 150 m
Approx. 0.5 m to 500 m
Measuring reference
from front edge (See 6 Physical dimensions)
Diameter of laser spot at target at a distance of
4mm @ 5m
8mm @ 10m
15mm @ 30m
Time for a measurement
Single measurement:
DLS-C(H) / FLS-C(H)
3)
Tracking:
DLS-C(H)
3)
FLS-C(H)
3)
Typical: 0.3 s to 4 s
Typical: 0.15 s to 4 s
Typical: 50 ms to 4 s
Light source
Laser diode 620-690 nm (red)
IEC 60825-1:2007; Class 2
FDA 21CFR 1040.10 and 1040.11
Beam divergence:0.16 x 0.6 mrad
Pulse duration: 0.45x10
-9
s
Maximum radiant power: 0.95 mW
Laser Life Time
typical 50'000h @ 20°C
ESD
IEC 61000-4-2
EMC
EN 61000-6-4
EN 61000-6-2
Power supply
9 ... 30V DC 0.6A for DLS-C / FLS-C
24 ... 30V DC 2.5A for DLS-CH /FLS-CH(Heating option)
Dimensions
150 x 80 x 55 mm
Temperature range during operation
2)
DLS-C 15 / DLS-C 30
DLS-CH 15 / DLS-CH 30
-10 °C to +50 °C
-40 °C to +50 °C
Temperature range during storage
-40 °C to +70 °C
Degree of Protection
IP65; IEC60529 (protected against ingress of dust and water)
Weight
DLS-C, FLS-C:
690 g
DLS-CH, FLS-CH:
720 g
Standard interface
1 serial asynchronous interface RS232
1 serial asynchronous interface RS422
1 SSI (only FLS-C(H))
1 programmable analog output 0/4 .. 20mA
2 programmable digital outputs
1 programmable digital input
1 digital output for error status
1) See 4.1 Measuring accuracy on page 14.
2) In case of permanent continuous measurement (tracking mode) the max. temperature is reduced to 45°C
3) Accuracy and measurement speed depend on configuration (See 8.3.2 Enhanced measuring Modes (sNuc) on page 25)
Distance Laser Sensor
Page 15/41
Содержание DLS-C 15
Страница 2: ......