PLC Cable
Supply voltage: The relay is powered from a 5 volt regulator inside the AFG Input
control: The relay state is controlled via a TTL signal from the AFG and is in a
“closed position” when a logic ‘1’ input is applied.
Output characteristics
Peak relay ac voltage:
350 volts
Continuous relay load current or peak ac voltage:
120 mA
Maximum relay peak load current:
300 mA
Typical relay contact resistance at 100 mA:
17 ohms
Isolation voltage between AFG and relay output:
1500 volts AC