Unit Configuration
Any settings that are specific to the unit can be set via the Operations Menu.
User Menu?
Yes=1 No=0
Press the 0 (zero) key, you see the following displayed:
Operations Menu?
Yes=1 No=0
Press the 1 (one) key. Follow the instructions to set the various options for the unit:
›
LCD Contrast (0-9) - Use the number keys 0 thru 9 to change the LCD
contrast. As you press a key you will see the contrast change. Press the #
key when you are happy with the setting
›
Enter Delay? (1-9 SEC) - Use the number keys 1 thru 9 to change the entry
delay. The entry delay is the number of seconds the doors will open for
following a successful access.
›
Exit Delay? (1-9 SEC) - Use the number keys 1 thru 9 to change the exit
delay. The exit delay is the number of seconds the doors will open for
following a Request To Exit (RTE) button being pressed.
›
Propped Door Alarm - Press 1 to turn this feature ON or 0 to turn this feature
OFF. The propped door delay requires door contacts to be installed. If this
feature is turned ON, you will be prompted to enter the Propped Door Delay
next.
›
Propped Door Delay (1-99 MIN) - Use the number keys entering values 1 thru
99 to change the delay period. This is the number of minutes the door can be
propped open before creating an alarm.
›
Security Level? (1-3) - Use the number keys 1 thru 3 to change the security
level. Level 2 is the default level. Level 1 is most tolerant to different finger
placement. Level 3 is the most secure and will require most accurate finger
placement on the fingerprint scanner.
›
Set Credentials - The default credentials for all units are PIN and Fingerprint
enabled. The db NEXIII also has an RFID reader incorporated into the unit.
RFID is turned OFF by default. Select 1 to change which credentials are
enabled, select 0 to retain the current settings.
›
If you chose to modify the credential settings you will be prompted to turn on
or off each of the 3 credentials. Press 1 to enable a credential or 0 to disable
it.
›
Press 1 when prompted to save the new configuration data.
Содержание dbNEXII
Страница 17: ...Digitus Biometrics Inc User Manual Models dbNEXII dbNEXIII dbSAI dbTRI Page 17 of 27 Appendix 1 Menu Maps ...
Страница 18: ...Digitus Biometrics Inc User Manual Models dbNEXII dbNEXIII dbSAI dbTRI Page 18 of 27 ...
Страница 19: ...Digitus Biometrics Inc User Manual Models dbNEXII dbNEXIII dbSAI dbTRI Page 19 of 27 ...
Страница 20: ...Digitus Biometrics Inc User Manual Models dbNEXII dbNEXIII dbSAI dbTRI Page 20 of 27 ...
Страница 21: ...Digitus Biometrics Inc User Manual Models dbNEXII dbNEXIII dbSAI dbTRI Page 21 of 27 ...
Страница 22: ...Digitus Biometrics Inc User Manual Models dbNEXII dbNEXIII dbSAI dbTRI Page 22 of 27 ...