background image

 

 

Troubleshooting Guide   

Problem 

Reason 

Suggestion 

The detector 

displays or 

sounds 

without 

detecting any 

target 

1.

 

The detector may 

receive interference 

and false signal from 

broadcast antenna and 

other electronic lines 

2.

 

The humidity of 

environment may be 

extremely high 

1. 

Change searching place 

2. 

Wait  for  some  time  to 

check again 

The detector 

sounds false 

signals. 

 

1.

 

Sensitivity set too high/ 

environmental 

electromagnetic 

interference 

2.

 

Sweeping the detector’s 

search coil too fast or at 

wrong angle 

3.

 

Using 2 detectors in 

close proximity 

1. 

Reduce sensitivity 

2. 

Sweep the search coil 

more slowly and hold 

the detector correctly 

3. 

Keep two detectors at 

least 6 meters(20’) apart 

The detector 

does not 

detect 

anything 

1.

 

Sensitivity set too low 

2.

 

Target range is 

eliminated 

3.

 

Search coil is not 

parallel to the ground 

1.

 

Increase sensitivity 

2.

 

Recover all target range 

3.

 

Adjust the search coil 

angel to be parallel to 

the ground 

LCD display 

multiple target 

categories or 

emits several 

sounds at once 

1.

 

There may be over one 

kind of metal targets 

2.

 

The detector can’t 

identify the target. 

Sometimes, oxidized 

metal also causes the 

excursion of target 

arrow and tone. 

1.

 

Reduce the sensitivity to 

eliminate the detection 

of the deeper target 

2.

 

Sweep the search coil 

with different angles 

The detector 

does not 

function. 

1.

 

Five-pin cable not 

connected well 

2.

 

Dead battery 

1.

 

Re-plug it properly 

2.

 

Replace batteries 

 

 

Содержание QP2308

Страница 1: ...Model Instruction Manual Metal Detector with Waterproof Coil QP2308...

Страница 2: ...cklight MODE Press it to select desired operation mode There are four modes to be selected from MODE indicator on LCD INCREASE To increase the level of volume sensitivity and the range of discriminati...

Страница 3: ...lower stem and remove the knob connector Place the washers into the groove of the lower stem Then insert the stem and align the holes on the search coil bracket and the stem Push the connector throug...

Страница 4: ...ounter clockwise rotate to tighten the lock nut on the middle stem 6 Fix the control box on the S stem and tighten the fixing screw properly Wind the search coil cable around the stem Insert the searc...

Страница 5: ...roperly Never bury or burn them Cautions l Use only fresh alkaline batteries of required size l Do not mix the old and new batteries or different types of batteries l If you don t plan to use the dete...

Страница 6: ...CONTROL PANEL 1 LCD DISPLAY 2 CONTROL BUTTONS POWER Press the button to power on the detector Press it again to power off the detector VOLUME BACKLIGHT Short press for adjusting volume level Press...

Страница 7: ...n working with SENS and DISC DECREASE To decrease the level of sensitivity and the range of discrimination working with SENS and DISC PP Pinpoints the location of the target accurately SEARCH MODES Th...

Страница 8: ...r SENS level and battery level Note If no button is pressed or no target is detected within about 15 minutes the detector will turn off automatically Step 2 Testing and using the detector To learn how...

Страница 9: ...e eliminated by using DISC mode But silver target such as one dollar coin or 25 cent can t be eliminated Because they are valuable c To pick up the eliminated target ID simply press and the recovered...

Страница 10: ...s automatically Iron target ID will not appear on LCD In this mode the detector will not respond to iron If you don t want to detect iron you can use JEWELRY mode for detection Step 3 Adjusting sensit...

Страница 11: ...search coil A sweep with the side of coin over search coil might cause false indication and unstable display of target TARGET INDICATIONS Target Iron 5 cent Nickel Jewelry Pull tab Jewelry 1cent zinc...

Страница 12: ...er Do not place it in tall grass or weeds Step 6 Hold the search coil level to the ground about 1 2 inches above the surface slowly move the search coil over the area where you placed the sample sweep...

Страница 13: ...l As the light consumes more power it s better to turn off the backlight in normal environment PP PINPOINT After you find a metal object you can use PP to pinpoint the target 1 Press PP button PP on...

Страница 14: ...al interference surrounding the target In area of highly mineralized ground or fertile ground or wet sand the detector will sound even if there is no metal In this case you can lower the sensitivity M...

Страница 15: ...old the detector correctly 3 Keep two detectors at least 6 meters 20 apart The detector does not detect anything 1 Sensitivity set too low 2 Target range is eliminated 3 Search coil is not parallel to...

Страница 16: ...Distributed by Electus Distribution Pty Ltd 46 Eastern Creek Dr Eastern Creek NSW 2766 Australia Ph 1300 738 555 Int l 61 2 8832 3200 Fax 1300 738 500 www electusdistribution com au...

Отзывы: