![Digital Watchdog E.S.T. DW-ESTBLKBD Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/digital-watchdog/e-s-t-dw-estblkbd/e-s-t-dw-estblkbd_user-manual_2500180016.webp)
DW E.S.T. (Elevated Skin Temperature) System
-16-
The
“Functions”
bar includes the software’s settings below:
<Function Options>
1.
Face Detection Reset
If facial detection is not working properly, or the camera’s orientation was changed, use this button
to restart the "
Initializing...
" process. During the process, the "
Initializing...
" term will appear in the
software’s view.
Note:
It is recommended to start the “Face Detection Reset” with no people in the camera’s view.
Keep people and moving objects away 32ft (10m) from the camera’s view for 3-10 seconds
as the cameras adjust.
2.
Photo
Save a JPEG image of the current view. The saved image will appear in the
History
log on the
bottom-left. Click on the folder icon to open the folder location on the computer. Click on the image
icon to open the captured image.
To change the directory where the images are saved, click the “
Settings
” button on the top
navigation bar. Under
General Settings
, click on “
Automatic Storage Path
” and click on the “
...
”
button on the right.
The file name format depends on the date/time format set in the settings buttons on the top
navigation bar:
•
YYYY / MM / DD: FSM_Export_YYYMMDD_HHMMSS.JPG
•
MM / YYYY / DD: FSM_Export_MMYYYYDD_HHMMSS.JPG
•
DD / MM / YYYY: FSM_Export_MMDDYYYY_HHMMSS.JPG