The following tables contain Contact ID and Automatic SIA
format reporting codes. For more information on reporting
code formats and notes about individual reporting codes,
(
see Section 5.6 Communicator Programming PWS Sect
6
).
Contact ID
The first digit (in parentheses) will automatically be sent by
the control. The second two digits are programmed to indi-
cate specific information about the signal. For example, if
zone 1 is an entry/exit point, you could program the event
code as [34]. The central station would receive the following:
*BURG - ENTRY/EXIT - 1 where the “1” indicates which
zone went into alarm.
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product follows
the level 2 specifications of the SIA Digital Communication
Standard - October 1997. This format will send the Account
Code along with its data transmission. The transmission will
look similar to the following at the receiver:
N Ri01
BA 01
N
=
New Event
Ri01 =
Partition /Area Identifier
BA
=
Burglary Alarm
01
=
Zone 1
NOTE:
A system event will use the Area Identifier Ri00.
A p p e n d i x A : R e p o r t i n g C o d e s
Section #
Reporting Code
Code Sent When...
Dialer
Direction*
Automatic
Contact ID
Codes
SIA Auto Rep
Codes**
[320]-[323]
Zone Alarms
Zone goes into alarm
A/R
See Table 3
See Table 3
[324]-[327]
Zone Restorals
Alarm condition has been restored
A/R
[328]
Duress Alarm
Duress code entered at keypad
A/R
(1) 21
HA-00
[328]
Opening After Alarm
System disarmed with alarm in memory
A/R
(4) 58
OR-00
[328]
Recent Closing
Alarm occurs within two minutes of system arming
A/R
(4) 59
CR-00
[328]
Zone Expander Supervisory
Alarm/Rest.
Panel loses/restores supervisory transmission over the Keybus
from zone expansion modules, or keypads with zone inputs
A/R
(1) 43
UA-00/UH-00
[328]
Cross Zone (Police Code)
Alarm
Two zones on the same partition go into alarm during any given
armed-to-armed period (incl. 24Hr zones)
A/R
(1) 4A
BM-00/BV-00
[328]
Burglary Not Verified
A/R
(3) 78
XM-00
[328]
Alarm Cancelled
A/R
(4) A6
BC-00
[329]
[F] Key Alarm/Rest.
Keypad fire alarm (alarm and restore rep. codes sent together)
A/R
(1) 15
FA-00/FH-00
[329]
[A] Key Alarm/Rest.
Keypad auxiliary alarm (alarm and restore rep. codes sent
together)
A/R
(1) AA
MA-00/MH-00
[329]
[P] Key Alarm/Rest.
Keypad panic alarm (alarm and restore rep. codes sent together) A/R
(1) 2A
PA-00/PH-00
[329]
Aux Input Alarm/Rest
Option#23/24: a panic button wired to PGM 2 is pressed/access
code is entered
Option #04: a 2-wire smoke detector wired to PGM 2 goes into
alarm/alarm is cleared.
A/R
A/R
(1) 4A
(1) 11
UA-99/UH-99
FA-99/FH-99
[330]-[337]
Zone Tamper/Restoral
Zone is tampered / tamper condition restored
T/R
(1) 44
TA-ZZ/TR-ZZ
[338]
General System Tamper/
Rest.
Enrolled module with tamper inputs has a tamper alarm/all mod-
ule tampers restored
T/R
(1) 45
TA-00/TR-00
[338]
Keypad Lockout
Maximum number of incorrect access codes has been entered at
a keypad
T/R
(4) 21
JA-00
[339-341]
Closings
System armed (user 01-34, 40-42 indicated)
O/C
(4) A1
CL-UU
[341]
Partial Closing
One or more zones bypassed when system armed
O/C
(4) 7A
CG-ZZ
[341]
Special Closing
Closing (arming) using one of the following methods: quick arm,
auto arm, keyswitch, function key, maintenance code, DLS soft-
ware, wireless key
O/C
(4) AA
CL-00
[341]
Late to Close
Whenever the Auto-arm prealert sounds (if the Late to Close
option is enabled)
O/C
(4) A4
CI-00
[341]
Exit Fault
O/C
(3) 74
EE-00
[342-344]
Openings
System disarmed (user 01-34, 40-42 indicated)
O/C
(4) A1
OP-UU
[344]
Auto-arm Cancellation
Auto-arm cancelled
O/C
(4) A5
CE-00
[344]
Special Opening
Opening (disarming) using one of the following methods: key-
switch, maintenance code, DLS software, wireless key
O/C
(4) AA
OP-00
[345]-[346]
Battery Trouble/Rest.
PC1616/PC1832/PC1864 battery is low/battery restored
MA/R
(3) A2
YT-00/YR-00
[345]-[346]
AC Line Trouble/Rest.
AC power to control panel is disconnected or interrupted/AC
power restored (Both codes follow AC Failure Comm. Delay.)
MA/R
(3) A1
AT-00/AR-00
[345]-[346]
Bell Circuit Trouble/Rest.
Open or short circuit detected across bell terminals/bell circuit
restored
MA/R
(3) 21
YA-99/YH-99
[345]-[346]
Fire Trouble/Rest.
Trouble occurs/restores on a fire zone
MA/R
(3) 73
FT-00/FJ-00