37

zone.  A  different  reporting  code  can  be  programmed  for
each zone for identification. 

[334]-[337] - Tamper Reporting Codes, Zones 1 to 64
The 

Zone Tamper Restoral

 Reporting Code will be transmit-

ted immediately when the tamper condition is restored.

[338] - Miscellaneous Tamper Reporting Codes

General System Tamper:

 a 

General System Tamper

 Reporting

Code will be transmitted when the tamper zone on any mod-
ule is violated.

General  System  Tamper  Restoral:

  the  General  System

Tamper  Restoral  Reporting  Code  will  be  transmitted  when
the tamper zone on the module is restored.
Keypad Lockout: the panel will transmit the Keypad Lock-
out Reporting Code if the lockout is activated.

[339]-[340] - Closing (Arming) Reporting Codes, Zones 
1-32
The panel will transmit a Closing Reporting Code to indicate
a  Partition(s)  is  armed.  A  different  reporting  code  can  be
transmitted for each User Code, Partition Master Code and
System Master Code to identify who armed the partition(s).

[341] - Miscellaneous Closing (Arming) Reporting Codes

Closing  by  Duress  Code  33/34:

  a  closing  by  Duress  Code

Reporting Code will be transmitted in addition to the Duress
reporting code if a Partition(s) is armed using a Duress Code

Closing by Master or Supervisory Code:

 the panel will trans-

mit  a  Closing  Reporting  Code  to  indicate  a  Partition(s)  is
armed.  A  different  reporting  code  can  be  transmitted  for
each  User  Code,  Supervisory  Code  and  System  Master
Code to identify who armed the Partition(s).

Partial  Closing:

  a  Partial  Closing  Reporting  Code  will  be

transmitted  if  a  Partition  is  armed  with  zones  manually
bypassed.  The  code  will  also  be  transmitted  if  a  Partition
Auto Arms with zone(s) in violation.

Special  Closing: 

a  Special  Closing  Reporting  Code  will  be

transmitted  if  the  Partition(s)  is  armed  using  any  of  the  fol-
lowing methods:

• Qui ck Arm
• Auto Arm
• Arming via the DLS Software
• Arming via Keyswitch
• Away Function Key Arming
• Arming with the Maintenance Code
• Stay Function Key arming

Late to Close:

 a Late to Close Reporting Code will be trans-

mitted if a partition isn't armed before the Auto-arm start time
when  the  late  to  close  option,  (Section  017,  option  5)  is
enabled.

[342]-[343] - Opening (Disarming) Reporting Codes  
Access Codes 1 to 32
The panel will transmit an 

Opening Reporting Code

 to indi-

cate partition(s) is disarmed. A different reporting code can
be transmitted for each user code, partition master code and
system master code to identify who armed the partition(s).

[344] - Miscellaneous Opening (Disarming) Reporting 
Codes
Opening by Duress Code 33/34: 
This Reporting Code will
be  transmitted  in  addition  to  the  duress  reporting  code  if  a
Partition(s) is disarmed using a Duress Code
Opening  by  Master  or  Supervisory  Code:  The  panel  will
transmit this reporting code to indicate a Partition(s) is armed.
A  different  reporting  code  can  be  transmitted  for  each  User
Code, Supervisory Code and System Master Code to identify
who armed the Partition(s).
Auto  Arm  Cancellation:  This  reporting  code  is  transmitted
when the Auto Arming sequence is canceled or Postponed

Special Opening: A Special Opening Reporting Code will be
transmitted if the Partition(s) is disarmed using any of the fol-
lowing methods:

• Disarming using the Maintenance Code
• Disarming via the DLS Software
• Disarming via keyswitch

[345] - Maintenance Alarm Reporting Codes

Battery  Trouble  Alarm:

  the  panel  will  transmit  a  Battery

Trouble  Alarm  Reporting  Code  when  the  backup  battery
drops below 11.5 V

DC

.

AC Failure Trouble Alarm:

  the panel will transmit an AC Fail-

ure Trouble Alarm Reporting Code when the AC to the panel
is  lost  and  the  AC  Failure  Communication  Delay  timer
expires. 

Bell  Circuit  Trouble  Alarm:

    a  Bell  Circuit  Trouble  Alarm

Reporting  Code  will  be  transmitted  immediately  if  an  open
condition is measured on the Bell Output of the main panel.

Fire  Trouble  Alarm:

    a  Fire  Trouble  Alarm  Reporting  Code

will  be  transmitted  immediately  when  an  open  condition  is
measured on any Fire type zone. 

Auxiliary Power Supply Trouble Alarm: 

the Auxiliary Power

Supply Trouble  Alarm  Reporting Code  will be transmitted  if
the AUX output is shorted.

TLM  Trouble:

    a  TLM  Trouble  Reporting  Code  can  only  be

transmitted if an alternate communicator is being used. The
panel will only transmit the signal after the time programmed
for the TLM Trouble Delay. 

General System Trouble: 

a General System Trouble Report-

ing Code will  be  transmitted  if the panel detects any of the
following: 

• AC Power Failure
• Low Battery
• AUX Output Trouble
• Output #1 on the PC5200/PC5204 Power Supply/Output

Module.

• T-Link Troubles

General  System  Supervisory  Trouble:

    a  General  System

Supervisory  Trouble  Reporting  Code  will  be  transmitted  if
any module goes missing from the Keybus. If the module is a
zone  expander  the  panel  will  also  transmit  the 

Zone

Expander Supervisory Alarm Trouble

 Reporting Code. 

[346] - Maintenance Alarm Reporting Codes
Battery  Trouble  Restoral
:  the  Battery  Trouble  Restoral
Reporting Code will not be transmitted until the battery has
been charged over 12.5 V

DC

.

AC Failure Trouble Restoral: the AC Failure Trouble Resto-
ral  Reporting  Code  will  be  transmitted  once  AC  power  has
been  restored  for  the  amount  of  time  programmed  for  AC
Failure Communication delays.
Bell  Circuit  Trouble  Restoral:  the  Bell  Circuit  Trouble
Restoral Reporting Code will be transmitted as soon as the
open condition on the bell output is corrected.
Fire Trouble Restoral: the Fire Trouble Restoral Reporting
Code will be transmitted when the correct resistance value is
measured on any Fire type zone. 
Auxiliary Power Supply Trouble Restoral:  the panel con-
stantly checks the AUX output, when the excessive current
draw is removed the panel will reset the output and transmit
an Auxiliary Power Supply Trouble Restoral Reporting Code.
TLM  Restoral:  the  TLM  Restoral  Reporting  Code  will  be
transmitted immediately after the trouble is restored.
General System Trouble Restoral: a General System Trou-
ble  Restoral  Reporting  Code  will  be  transmitted  when  the
panel detects none of the following: 

• AC Power Failure
• Low Battery
• AUX Output Trouble

Содержание PC1616

Страница 1: ...gher PC1616 PC1832 PC1864 This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual sh...

Страница 2: ...bus Terminals RED BLK YEL GRN 6 Programmable Outputs PGM1 to PGM4 6 Zone Input Terminals Z1 to Z8 6 Telephone Connection Terminals TIP RING T 1 R 1 6 2 3 Wire Routing for Power Non Power Limited 6 2 4...

Страница 3: ...one Assignments 35 Partitions and Zone Assignment 35 5 5 Communicator Programming 35 Communicator Telephone Numbers 35 301 First Telephone Number 35 302 Second Telephone Number 35 303 Third Telephone...

Страница 4: ...toring 51 6 1 Partitions and Fire System Configuration 51 Fire Configuration 1 51 Fire Configuration 2 51 6 2 Fire Zones 51 Standard Fire Operation 51 Auto Verify Fire 51 Four Wire Smoke Detector Zone...

Страница 5: ...your programming Be sure to record all your system programming in the Programming Worksheets If adding modules to your PowerSeries Control Panel refer to the Installation Instructions that come with...

Страница 6: ...upervision for loss of primary power source AC Fail battery fail or battery low voltage Battery Trouble with indication provided on the keypad Internal clock locked to AC power frequency Operating Env...

Страница 7: ...etails NOTE Only the first 32 zones on the PC1616 PC1832 PC1864 system can be used as wireless zones NOTE PC1616 expandable to 16 zones only PC5200 Power Supply Output Module The PC5200 can provide up...

Страница 8: ...with removable door UL ULC Household Fire ULC Commercial Burglary Made with 22Ga steel Approximate Dimensions 287mm x 297mm x 76mm 11 3 x 11 7 x 3 0 PC5003C Hinged Door Description Main Control Cabine...

Страница 9: ...ete description of how to pro gram the panel Section 5 0 contains complete descriptions of the various programmable features what options are available and how the options function The Programming Wor...

Страница 10: ...inimum 6 4mm separation must be maintained at all points between power limited and non power limited wiring and connections NOTE Wire entry for power limited wiring must be sepa rated by a different e...

Страница 11: ...t enter 0 for Global operation or enter 1 8 for Partitions 1 8 2nd digit enter 1 to 8 for Slot Assignment 5 Press the key twice to exit programming 6 Continue this procedure at each keypad until all h...

Страница 12: ...matically search for all modules connected to the system for the next 60 seconds Do not perform any other oper ations during this 60 second period 6 Once the search is complete enter section 903 to co...

Страница 13: ...ions for DEOL End of Line Resistors Section 013 Option 1 Double End of Line Resistors Section 013 Option 2 Fire Zone Wiring 4 wire Smoke Detectors All zones defined as Fire see section 5 2 Basic Progr...

Страница 14: ...ngle End of Line and Double End of Line To connect the PGM output on a PK55XX RFK55XX key pad run one wire to the Z P terminal and the other to R PK55XX RFK55XX NOTE End of line resistors must be plac...

Страница 15: ...ter the corresponding HEX digit 1 A 2 B 3 C 4 D 5 E 6 F After the correct HEX digit is entered the Ready light will continue to flash If another HEX digit is required press the corresponding number If...

Страница 16: ...hrough the entry exit door the panel will bypass all Stay Away type zones The panel is now Stay armed The Bypass light will remain on to inform the home owner that the interior protection is bypassed...

Страница 17: ...d The keypad will display Zone Search Zone Name 3 Enter the two digit number of the zone s to be bypassed 01 64 You can also use the keys to find the zone to be bypassed and then press to select the z...

Страница 18: ...C5400 Printer module has a fault and is off line or T Link Troubles Users can view specific conditions in the Event Buffer Light 4 General System Tamper Tamper has been detected from a module Light 5...

Страница 19: ...rtition number 1 8 to toggle it on or off NOTE Partition programming is NOT supported by the fol lowing keypads PC5508 Z PC5516 Z PC5532 Z versions v2 00 and lower LCD5500 Z version 2 x and lower LCD5...

Страница 20: ...tempt to call the downloading computer NOTE The downloading computer must be waiting for the panel to call before downloading can be performed 7 For Future Use 8 User Walk Test 6 User Functions allows...

Страница 21: ...xit delay The Quick Arm feature must be enabled for this key to function Section 015 Option 4 If Quick Arming is not enabled the user must enter their access code after pressing the function key in or...

Страница 22: ...selected the Trouble light will turn on if a trouble con dition is present and the Armed light will turn on if all the partitions are armed To select a partition the user must press and hold one of k...

Страница 23: ...and transmission by the communicator is delayed by 30 seconds If the alarm is acknowledged by pressing any key within 30 seconds the bells will silence and the transmission will be aborted If the ala...

Страница 24: ...armed in the Away Mode This zone type is useful for motion detectors in an installation that must not follow the Entry Delay after a Delay zone is violated but must still retain the Stay Away function...

Страница 25: ...ing Code Section 349 Bell Circuit Trouble Restoral Reporting Code Section 350 Temporal Three Fire Signal Enable Disable Section 013 Option 8 Fire Bell Continuous Section 014 Option 8 006 Installer s C...

Страница 26: ...e exit delay begins 07 Keypad Buzzer Follow This output will activate switch to ground when any of the following events occur and will remain active for as long as the keypad buzzer is active Door Chi...

Страница 27: ...PGM type will activate 22 Command Output 4 This output is activated by entering the 7 4 command The configuration of the corresponding attributes deter mines how this PGM type will activate 23 Silent...

Страница 28: ...ication of alarms and the initiation of the confirmation time the toggle option TX Delay During Entry Only must be enabled The transmission delay attribute must also be enabled for all zones and the c...

Страница 29: ...emory the bell will emit a series of three squawk pairs to indicate the alarm memory NOTE If you enable the Bell Squawk on Arming Disarming the bell will sound arm disarm bell squawks for all access c...

Страница 30: ...call direc tion options Fire Auxiliary and Panic key NOTE The Fire Auxiliary Panic keys will operate even if Keypad Blanking and Keypad Lockout are active See Section 5 3 Basic Programming PWS Sect 3...

Страница 31: ...ave Mode ON Power Save Mode Enabled If AC power fails all keypad lights including backlighting will be shut OFF The keypad lights will come back ON after a keypress Entry delay Audible Alarm or keypad...

Страница 32: ...the Auto arm and Test Transmissions programming OFF Daylight Savings Time Disabled The panel will make no automatic time adjustments for Daylight Sav ings time 7 For Future Use 8 Bell Squawk on Away A...

Страница 33: ...larm when faulted while stay armed Zone types 9 24 Hour Supervisory 12 24 Hour Hold Up 26 24 Hour Non Alarm do not generate an audible alarm in any armed state stay or away OFF Wireless Zone Fault Doe...

Страница 34: ...try Procedure The following zone type alarms will follow bell delay if a zone violation occurs while entry delay is active on the partition Instant Interior Interior Stay Away Delay Stay Away 24 Hr Su...

Страница 35: ...not be locked out after an alarm occurs 5 Engineer s Reset ON Engineer s Reset Enabled If the panel has gone into alarm during the previous armed period or if a 24 Hour alarm has occurred armed or dis...

Страница 36: ...ate tamper alarms The panel will generate a silent trouble NO trouble beeps but the Trouble LED is turned ON called RF Device Delinquency that s only viewable in 2 Trouble Mem ory The user can overrid...

Страница 37: ...e system trouble beeps will not be sounded at the keypad OFF Trouble Beeps will Sound Every 10 Seconds When a trouble is detected on the system trouble beeps will be sounded at the keypad NOTE This op...

Страница 38: ...ll not log or transmit If a second zone is violated within the Cross Zone Timer s seconds duration the panel will go into the appropriate alarm sequence and will communicate both zone alarms No Police...

Страница 39: ...233 Partition 5 Zone Assignments Sections 234 to 241 Partition 6 Zone Assignments Sections 242 to 249 Partition 7 Zone Assignments Sections 250 to 257 Partition 8 Zone Assignments Sections 258 to 265...

Страница 40: ...ral Reporting Codes Zones 1 to 64 If the Restoral on Bell Timeout option is selected the panel will send the Zone Restoral Reporting Code for the zone when the alarm output times out AND the zone is s...

Страница 41: ...o Arm Cancellation This reporting code is transmitted when the Auto Arming sequence is canceled or Postponed Special Opening A Special Opening Reporting Code will be transmitted if the Partition s is...

Страница 42: ...eporting Code in place of the standard Peri odic Test Transmission if any of the following conditions exist Fire Zone Trouble Zones 1 64 Battery Trouble PC1616 PC1832 PC1864 PC520X Fire Zone Alarm Zon...

Страница 43: ...med as 00 the panel would not report If the SIA Sends Automatic Reporting Codes option is dis abled the panel will operate as follows 1 If the reporting code for an event is programmed as 00 or FF the...

Страница 44: ...mple If you program the zone 3 alarm reporting code as 31 the panel will send event code 1 in channel 3 The panel will send the number 5 for each of the other channels so that the event code will look...

Страница 45: ...tores This value defines the number of attempts alarm and restore pairs per zone that the panel will log and communicate before it shuts down for that zone swinger shutdown Valid entries are 000 to 01...

Страница 46: ...his interval is in minutes or days is determined on Section 702 Option 3 NOTE If using Test Transmission Exception a value of 001 will disable the Test Transmission Exception feature Wireless Zone Low...

Страница 47: ...y armed Activity on Bypassed zones does not affect this timer The timer is reset on arming OFF Delinquency Follows Arming Closing Delinquency This reporting code is sent whenever the programmed number...

Страница 48: ...2 Walk Test Communication ON Zone Alarms Communicate during Walk Test Enabled Zone alarms that occur during Walk Test will communicate if programmed to do so OFF Zone Alarms Communicate during Walk T...

Страница 49: ...will be busy for the duration of the PC Link connection The status LEDs will display the current system status on the keypad where the PC Link was initiated For more information on connect ing the PC...

Страница 50: ...sheets for the PGM output types defaults CAUTION Select the normal and active states of each PGM output to ensure that undesirable output states do not occur after a loss and restore of AC power If yo...

Страница 51: ...Trouble 8 Loss of Clock Loss of Time Trouble PGM Output Types 10 System Event 1 Burglary Delay Instant Interior Stay Away and 24 Hour Burg Zone Types 2 Fire F Key Fire Zone 3 Panic P Key and Panic zon...

Страница 52: ...l access codes on the system will be 4 digits in length For any existing codes the last 2 digits are removed 6 Busy Tone ON Busy Tone Detection Enabled If these tones are detected the communicator wil...

Страница 53: ...n 901 Zones do not have to be restored to stop the test After the test is complete check the Event Buffer to ensure that the Audible Silent 24 hr PGM alarms have been restored NOTE The Alarm Memory is...

Страница 54: ...section 991 again 993 999 Factory Defaults On occasion it may be necessary to default the main control panel or one of the modules that can be connected There are several different defaults available...

Страница 55: ...stor this will be indicated as a Zone Trouble Ground Fault resistance 40k to earth ground indicated as a Ground Fault Trouble on PC5700 zone 7 Typical Fire Devices used on this zone type are Heat Dete...

Страница 56: ...entering 7 2 in order to reset smoke detectors Subsequent Alarm Operation If the alarm notification appliances have been silenced manually or automatically and a subsequent fire alarm is initiated the...

Страница 57: ...ire Keys on any keypad are pressed for two seconds NOTE For commercial applications do not program the F key for keypads that are readily accessible by the public For more information regarding this k...

Страница 58: ...pro grammed as not bypassable Casual Users The installer should caution the user s not to give system information to casual users e g codes bypass methods etc to baby sitters or service people Only th...

Страница 59: ...Cancel Annunciation 328 8th entry Access to the reporting code for Alarm Cancelled Annunciate that a Cancel was transmitted Default Enabled Required Duress Feature 5 Master Code 33rd and 34th entries...

Страница 60: ...ed A R 4 A6 BC 00 329 F Key Alarm Rest Keypad fire alarm alarm and restore rep codes sent together A R 1 15 FA 00 FH 00 329 A Key Alarm Rest Keypad auxiliary alarm alarm and restore rep codes sent tog...

Страница 61: ...e TLM Trouble Restore occurs on the PC5700 MA R 3 52 LR XX A R alarms restorals T R tampers restorals O C openings closings MA R miscellaneous alarms restorals T test transmissions UU user number user...

Страница 62: ...e power from the control panel must be UL Listed for the intended application and operate over the range of 11 6 12 6VDC residential 12 0VDC commercial The DSC Bravo Series are recommended UL Listed m...

Страница 63: ...rsons b The connection to the mains supply must be made as per the local authorities rules and regulations An appropriate disconnect device must be provided as part of the building installation Where...

Страница 64: ...tion WARNING High Voltage Disconnect AC Power and telephone lines before servicing WARNING 220 240V 50 60Hz 200mA AC PC5003C Cabinet Shown Use Model Power UC1 for 2 Battery Installations CON1 BAT BAT...

Страница 65: ...ual NOTE Do not combine the 2 wire smoke detector and 4 wire smoke detector on PGM2 only 2 wire smoke detectors on PGM2 SMOKE DETECTOR POWER 12 VDC IN OUT NO ALM OUT IN BLK WHT RED GRN LATCHING 4 WIRE...

Страница 66: ...International Programming 47 K Key 26 Key Annunciation 26 Keybus Fault 29 Keypad Assignment 7 Keypad Blanking 27 Keypad Buzzer Follow 22 Keypad Commands 12 Keypad Lockout 24 Keypad Lockout Options 24...

Страница 67: ...It is important that a security system be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it does not pro vide the protection...

Страница 68: ...ill notify you in advance that temporary discontinuance of service may be required But if advance notice is not practical the Telephone Company will notify the customer as soon as possible Also you wi...

Отзывы: