Rev C August 2009
Page 6.3
Digital Projection
TITAN sx+600/700.
User Manual
6. Maintenance
Changing the air filter
Turn the power OFF and allow the lamp to cool for 5 minutes.
Unscrew the four captive finger screws securing the rear door - the door is
tethered, so cannot be removed completely.
Pull out both air filters.
Fit two new air filters, making sure that they are each the correct way around, as
shown below.
Re-fit the rear door, making sure that the door tether is not trapped, and tighten
the four screws.
•
•
•
•
•
Notes
Always allow the lamp to cool
for 5 minutes before:
- disconnecting the power
- moving the projector
- changing the lamp
The air filter should be changed
regularly:
- In a clean environment such
as an office, change after 2000
hours, at the same time as the
lamp is changed.
- In a dusty or smoky
environment such as a theatre
or public area, more frequent
changes may be necessary.
Opening the rear door will
switch the projector OFF.
The projector cannot be
operated until the door is fully
closed.
Filter
side
Foam
side
Foam
side
Downloaded From projector-manual.com Digital Projection Manuals