background image

12 

XR2500F User’s Guide 

System Setup

System Setup 

XR2500F User’s Guide 

13

User Profiles Reference

Menu Display

Privilege

ARM

NO

YES

Arm

DIS

NO

YES

Disarm

ALM SLNC

NO

YES

Alarm Silence

SNSR RST

NO

YES

Sensor Reset

DOOR ACS

NO

YES

Door Access

ARM AREA

NO

YES

Armed Areas

OUTPUTS

NO

YES

Outputs ON/OFF

ZN STATS

NO

YES

Zone Status

BYPAS ZN

NO

YES

Bypass Zones

ZONE MON

NO

YES

Zone Monitor

SYS STAT

NO

YES

System Status

SYS TEST

NO

YES

System Test

PROFILES

NO

YES

User Profiles

USR CODE

NO

YES

User Codes

SCHEDULS

NO

YES

Schedules

TIME

NO

YES

Time

DIS EVNT

NO

YES

Display Events

SERV REQ

NO

YES

Service Request

FIRE DRILL

NO

YES

Fire Drill

EXTEND

NO

YES

Extend Schedules

TEMP CODE

NO

YES

Temporary User Code

ANTI PASS

NO

YES

Anti-Passback

ALOW: 1234

___ ANY

Allow: Shift/Time Access

RE ARM DLY

0 – 250

Re-Arm Delay

Changing User Profiles

1.  Access the User Menu.
2.  Press COMMAND until USER PROFILES? displays.
3.  Press any Select key.  The keypad displays ADD  DEL  CHG.
4.  Press the far right Select key, under CHG.  
4.  At  the  PROFILE  NO:  -  option,  enter  a  profile  number  and 

press COMMAND.  The display changes to PROFILE NAME.

5.  Press any Select key to display -.  Enter a profile name of up 

to 16 characters.  The default Profile Name uses the Profile 

Number.  Enter the name and press COMMAND.

6.  At  the  Arm/Dis  AREAS:  option,  enter  the  area  numbers 

(1-32) for arming and disarming assigned to this profile.

7.  The keypad displays ACCESS Areas: .  Enter the area numbers

(1-32) assignment to allow door access for this profile.  Press 

the COMMAND key.

8.  The keypad displays OUTPUT GROUP: -.  Enter the number 

(1 through 20) for the Output Group assigned to this profile.  

Press the COMMAND key.

 9.  The  keypad  displays  each  of  the  menus  as  shown  in  the 

Profile Table.  You then enable or disable the menu function 

for  this  profile  number.    Select  YES  or  NO  and  press  the 

COMMAND key to advance to the next menu selection.

10. When  you  complete  Selecting  all  User  Profile  menu 

assignments,  the  keypad  displays  the  PROFILE  CHNGD 

message for 4 seconds, indicating the profile is changed.

TEMP CODE

When  you  select  YES  for  this  menu  option,  and  this  profile  is 

assigned to a user code (see next section), the keypad displays 

TEMP  EXPIRE  DATE:.    Enter  the  ending  date  for  the  profile  to 

expire.    Default  is  seven  days  from  today.   The  system  deletes 

Temp users at 12:00 AM on the last date.

Содержание XR2500F

Страница 1: ...Fire Command Center User s Guide XR2500F...

Страница 2: ...notice Silencing an Alarm While the fire alarm horns strobes or sirens are sounding use one of the following methods to silence the alarm 1 Turn the keyswitch to enable the four function keys Then pre...

Страница 3: ...nd Center 1 User Menu 1 The Fire Command Center 2 Using the Keypad 3 Four Function Keys 4 Remote Fire Command Center 5 Special Fire Command Center Displays 5 Special Fire Command Center Tones 6 Fire C...

Страница 4: ...one Status Browser 21 Outputs On Off Browser 22 Output Groups Browser 22 Change User Profiles Browser 23 Add User Codes Browser 23 Delete User Codes Browser 24 Change User Codes Browser 24 Entering Us...

Страница 5: ...Decide where to meet Prearrange a meeting place outside and away from where emergency personnel are likely to be working A neighbor s house or across the street in the front of the house are good loca...

Страница 6: ...iv XR2500F User s Guide This page intentionally left blank...

Страница 7: ...as Bypass Zones Zone Monitor Schedules About Your Addressable Fire Alarm Control Panel The Addressable Fire Alarm Control Panel is designed with your safety and comfort in mind It uses the latest in c...

Страница 8: ...to go back through displays while operating your system Press the Back Arrow key to back up through the list of User Menu functions or to make a correction by erasing the last character you entered Th...

Страница 9: ...he top row Select key under the language you want to use The language chosen continues to display at this keypad until another language is chosen If this is not programmed the option to select a langu...

Страница 10: ...use the top left Select key to make the tone lower Use the right Select key to make the tone higher Volume level Sets the keypad internal speaker volume level for key presses and prewarn conditions Du...

Страница 11: ...describes a condition on the system Below are some examples of the displays ALARM A 24 hour zone for example fire or panic or an armed burglary zone has been tripped Your system may sound bells or si...

Страница 12: ...department as soon as possible SYSTEM BUSY The Security Command system is performing another task of a higher priority This usually only takes a few moments Special Fire Command Center Tones Your keyp...

Страница 13: ...the order they display Menu Option Description ALARM SILENCE Silences an alarm bell or siren SENSOR RESET Resets smoke or glassbreak detectors that have latched due to an alarm condition OUTPUTS ON O...

Страница 14: ...ENSORS OFF for five seconds followed by SENSORS ON 4 The keypad automatically exits the User Menu Alarm Silence Silences the alarm bells or sirens during an alarm Alarm Silence allows you to turn off...

Страница 15: ...s ON and OFF 1 Access the User Menu 2 Press COMMAND until OUTPUTS ON OFF displays 3 Press any Select key to display OUTPUTS DOOR 4 Select the type of output you want to turn ON or OFF by pressing the...

Страница 16: ...that are currently armed You can scroll through the list by pressing the COMMAND key 3b Select BYPS for a list of zones that are currently bypassed 3c Select ALR for a list of zones that have gone int...

Страница 17: ...04 the panel model MODEL XR500N and then exits the User Menu System Test System Test is used to test the battery alarm bell or siren and communication to a central station The System Test function beg...

Страница 18: ...installation to be sent User Profiles Change User Profiles that define the authority of each user code in the system Several characteristics define the authority of each User Profile within the system...

Страница 19: ...splay changes to PROFILE NAME 5 Press any Select key to display Enter a profile name of up to 16 characters The default Profile Name uses the Profile Number Enter the name and press COMMAND 6 At the A...

Страница 20: ...near the trash is scheduled to be armed at all times When the custodian needs to remove trash program 10 minutes for the activity Or an overhead door only requires access when a delivery is made Prog...

Страница 21: ...profile number from 1 to 99 and press COMMAND The displays shows USER ADDED If BAT Batch was chosen in step 4 instead of ADD the next available user number is automatically selected and only steps 6 a...

Страница 22: ...ng you how to use the User Codes Add Delete and Change browsers Setting the Date and Time Allows you to change the current date and time displayed on the LCD keypad and used by the system Setting the...

Страница 23: ...vents for 45 days Any event older than 45 days automatically clears from the system memory Also once the full 12 000 events are stored any new event causes the oldest event to be cleared See Appendix...

Страница 24: ...ents or press SRT to define a new sort About the Display Events Section This section of the User s Guide shows the Display Events items While in the Display Events function use the COMMAND and Back Ar...

Страница 25: ...y 1 AUX2 Auxiliary 2 Event Types There are seven event type you may see here ALR Alarm TBL Trouble RST Restore FLT Zone Fault SVC Service smoke detector LOW Low battery MIS Missing wireless transmitte...

Страница 26: ...vent Displays This displays any problems with the system AC power battery or phone line s or any opening of a tampered panel box 32 Character Display Description TBL 11 41A 10 17 POWER An AC failure o...

Страница 27: ...zones Fire Panic Supervisory etc Press the COMMAND key to scroll through the zone names list EAST DOOR When the correct zone name displays press any SELECT key ZONE NO 0 1 2 Verify the zone number mat...

Страница 28: ...AND SELECT ZONE COMMAND Press COMMAND Outputs On Off Browser Access the User Menu Press the COMMAND key until OUTPUTS ON OFF displays Press the Select key under OUTPUTS or DOOR COMMAND OFFICE FRONT DR...

Страница 29: ...press any Select key to clear the profile name and use the data entry keys to enter a new name When you complete changes to the profile press COMMAND PROFILE 12 CHNGD COMMAND COMMAND COMMAND Add User...

Страница 30: ...er Codes Browser USER CODES ADD DEL CHG USER NUMBER 1 2 4 3 MIKE JONES COMMAN D Access the User Menu Press COMMAND until USER CODES displays Press the SELECT key under CHG At this prompt you can enter...

Страница 31: ...5 6 8 7 9 0 1 A B C 1 A B C 1 2 Once the letter you want displays press the number key above the next letter you want to enter You can enter up to 16 characters for each name into the keypad A 1 2 4 3...

Страница 32: ...that is outside of the assigned profile Check the user profile settings INVALID TIME A user code assigned to a specific schedule was entered outside of the valid schedule See Schedules and User Codes...

Страница 33: ...24 Displays ALARM 5 Alarm Cancelled 5 Alarm Not Sent 5 Area 3 Armed Area 6 Device 3 Enter Code 5 Invalid Area 6 Invalid Code 5 Invalid Profile 6 Invalid Time 6 Multi lingual Option 3 Service Required...

Страница 34: ...13 Programming Current Keypad Display Options 3 R Re Arm Delay 14 Remote Annunciator Keypad 5 Remote Fire Command Center 5 S Select keys 2 Sensor Reset 8 Service Request 17 Service Required 6 Shfit S...

Страница 35: ...This page intentionally left blank...

Страница 36: ...LT 0760 6 05...