Digital Monitoring Products
XR150FC/XR550FC Series Installation Guide
16
Annunciator Outputs
The four programmable annunciator outputs can be programmed to indicate the activity of the panel zones or
conditions occurring on the system. Annunciator outputs do not provide voltage. Instead, they switch voltage from
another source to ground. The outputs can respond to any of the conditions listed in Dry Contact Relays. Maximum
voltage is 30 VDC at 50 mA.
Model 300 Harness Wiring
Access the open collector outputs by installing DMP 300 Harness on the 4‑pin OUTPUTS header. The output locations
are shown below. For listed applications, devices connected to the outputs must be located within the same room as the
panel.
Model 860 Relay Module
Connect a Model 860 Relay Module to the OUTPUTS header on the panel to provide relays for outputs 3‑6. Use these
relays for electrical isolation between the alarm panel and other systems or for switching voltage to control various
functions. Power is supplied to the relay coils from a single wire connected to the panel auxiliary power Terminal 7.
The module includes one relay and provides three additional sockets for expansion of up to four relays. Mount
the 860 inside the panel enclosure using the 3‑hole pattern and plastic standoffs. Refer to the 860 Module Install Sheet
(LT‑0484) as needed. Relay Contact Rating is 1 Amp at 30 VDC (allows 0.35 power factor).
Table 6: Model 300 Wiring
Output Color
Wire
Output Color
Wire
3
Red
1
5
Green
3
4
Yellow
2
6
Black
4
Table 5: Model 431 Output Wiring
Output 1
Output 2
Contact
Color
Contact
Color
Normally Closed
Violet
Normally Closed
Violet with white stripe
Common
Gray
Common
White with gray stripe
Normally Open
Orange
Normally Open
Orange with white stripe